13. Error Code and Corresponding

Error code

Reason of error

Remark

Solution

E0

Alarm on the Circuit board is 

damaged

Alarm on the Circuit board is 

damaged

Need change the controller circuit 

board.

E1

The light in the sauna room 

is damaged.

The light in the sauna room 

is damaged, no lighting.

Need change the light in the sauna 

room.

E2

The heating tube of the 

sauna heater machine is 

damaged.

The sauna heater machine 

will not work.

Need contract with the supplier to 

check the machine and change the 

heating tube.

E3

Button scan is damaged.

There is no reaction when 

push the controller button.

Need change the controller circuit 

board.

E4

Open circuit in temperature 

detector connection.

Open circuit in temperature 

detector connection.

Need check the cable connection 

of the temperature detector, and 

make sure the connection is right.

E5

short circuit in the 

temperature detector 

connection.

short circuit in the 

temperature detector 

connection.

Need check the cable connection 

of the temperature detector, and 

make sure the connection is right.

E6

Temperature detector enter 

the ultra-high temperature 

protection.

The temperature of the 

sauna room is too high.

The sauna heater will stop heating 

and cut off the power 

automatically, once the detected 

temperature lower than 120

, the 

machine can restart work.

E7

Sauna room enter the ultra-

high temperature protection

The temperature of the 

sauna room is too high.

The sauna heater will stop heating 

and cut off the power 

automatically, once the detected 

temperature drops to 120

, the 

machine can restart work.

E8

The temperature detection 

in the sauna room is 

damaged.

The temperature detection 

in the sauna room is 

damaged.

Need change the temperature 

detection.

Содержание Hidro-HX45B

Страница 1: ...SAUNA HEATER With Digital Display External Controller USER MANUAL ...

Страница 2: ...ing protection could cause too temperature and a risk of burn 3 Must use qualified materials for the walls and ceiling 3 Guard Rails Please follow the minimum distances requirements in figure 2 if guardrails are desired around the heater 4 Digital display Controller This controller is splash proof You can install it near the sauna room Temperature detector must install on inside room wall please i...

Страница 3: ...na heater for details A heater resistant cable of 3 meters long is provided which can be extended to the outside of sauna room by normal weak current cables For cables connection of the thermostat please see the following figure 7 Installation of temperature detector 8 Limit control If the temperature is too high inside sauna room like the temperature controller break down the temperature limiter ...

Страница 4: ...na shall be less than half and hour Bathing too long may cause heart beating too fast light heartache feeling weak or dizzy Should the bather stop bathing immediately as soon as the above symptoms occur 3 Sauna bath may cause tension to the bather Thus one who is one of the followings should be directed by physician A Being pregnant B Having heart disease C Having high blood pressur D Having circu...

Страница 5: ...ble connection of the temperature detector and make sure the connection is right E5 short circuit in the temperature detector connection short circuit in the temperature detector connection Need check the cable connection of the temperature detector and make sure the connection is right E6 Temperature detector enter the ultra high temperature protection The temperature of the sauna room is too hig...