MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01

MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01

6.4.1 Inlet hardness

6.4.2 Outlet hardness

6.4.3 Forced regeneration

6.4.4 Regeneration time

6.4.- Programming

Always starting from the service state, at the same time press                +             for 3 seconds 

to enter the programming mode.

Set the hardness using     

Press                      to  confirm  and  move  onto  the  next 

parameter

Adjust residual hardness using                    , programme 

to 90 ppm

Press                    to  confirm  and  move  onto  the  next 

parameter

You can check in point 

8.5.- Residual hardness setting,

 in this manual,  how to make the adjustment 

residual hardness.

Adjust days using                      programme 7

Press                    to  confirm  and  move  onto  the  next 

parameter

By default, the programmed regeneration time is 2:00 am as it’s a time when generally there won’t 

be any water consumption and therefore there’ll be good pressure. If you want the regenerations 

to be at a different time for whatever reason, programme the desired time in this parameter.

Adjust hour using                     

programme 2

Confirm using 
Adjust minutes using                     

programme 00

Confirm using            And we’ll be put back to the 

service screen. The system has been programmed.

Once the valve has been programmed, it’s time to start up the system.

Make sure the softener’s inlet and outlet valve are 

closed and that the bypass is open to make sure 

there’s water available.

7.- INSTALLATION CHECK LIST

8.- START UP

Installation

Description

Ok?

System positioning
Hydraulic connections checked
Inlet-Outlet // Bypass connected correctly and 

sealed tight
Drainage connected correctly and sealed tight
Brine connected correctly and sealed tight
Overflow connected correctly and sealed tight
Electric connection
Programming carried out

8.1.- Bleeding air

Position the valve in the 

BACKWASH

 position.

Press         for 5 seconds  The softener will go into the 

BRINE UP

 cycle. Wait until it is totally positioned (the motor 

stops being heard and time starts to count down). 

When the softener is totally positioned, press and release         The softener will go into the 

BACKWASH

 cycle. 

When it’s totally positioned, unplug the transformer from the electric supply.

½ open the bypass inlet valve and let the bottle fill slowly. 

You’ll hear the air escaping down the drain. Keep it like this 

until all of the air has been removed. You’ll know as now 

water is being released into the drain and it doesn’t have 

any bubbles.

If you open it too much or too fast, you can damage the system and /or lose resin. 

In this position, you must listen to the air escaping slowly in the drainage line.

SOFTENER

SOFTENER

SOFTENER

SOFTENER

NEXT

NEXT

NEXT

NEXT

NEXT

NEXT

Introduce the hardness value of the water to be treated in PPM (mg/l CaCO3) (PPM= °F x 10)

Hidro-Water recommends leaving a residual hardness of between 80 and 100 PPM (mg/l CaCO3).

This is a safety measure to avoid water becoming stagnant for a prolonged period as this may 

biologically contaminate the resins.

   

 

REGEN

   

 

REGEN

Содержание KOBE WS1CI UF

Страница 1: ...KOBE USER INSTALLER S MANUAL MA EN DESCALCIFICADOR KOBE USR UF 3004 XX JD18V01 CLACK SOFTENER WATER CONDITIONING SYSTEM KOBE WS1CI UF ...

Страница 2: ... Connecting the brine line 13 5 4 Electrical connection 13 6 PROGRAMMING USER LEVEL INSTALLER 14 6 1 Button functionality 14 6 2 Setting the time 15 6 3 Service screen 15 6 4 Programming 16 6 4 1 Inlet hardness 16 6 4 2 Outlet hardness 16 6 4 3 Forced regeneration 16 6 4 4 Regeneration time 16 7 INSTALLATION CHECK LIST 17 8 START UP 17 8 1 Bleeding air 17 8 2 Fill verification 18 8 3 Suction verif...

Страница 3: ...The regeneration process consists of several stages with the finality of regenerating the resin bed and preparing it for a new work cycle The Kobe series softeners automatically start and carry out the alternation between service and regeneration phases without the user having to manipulate the machine Hidro Water S L wants to thank you for purchasing your new Kobe system We hope you enjoy the ben...

Страница 4: ...ess the system and also to fill up the salt tank The system must be placed on a flat surface protected from direct sunlight rain and humidity The system including the overflow and drainage lines must be placed out of freezing temperatures and those that are over 43ºC The system mustn t be installed near acid nor vapours or be exposed to products derived from petroleum to avoid the risks of deflagr...

Страница 5: ... and the installation itself from suspended matter impurities sand etc which are common in the distribution network drilling waters either on the surface or underground 5 3 Connecting the system to the water intake 5 3 1 Inlets and Outlets Accessories 1 Manual 2 Transformer 3 Inlet outlet connector set 4 Drainage connector 5 Bypass optional 5 2 Diagram Typical diagram of a domestic installation an...

Страница 6: ... 1 System installation is very straightforward and doesn t require any tools a Prepare all of the pieces that you re going to need b In the slot that s closest to the thread we must place the supporting washer white on the inlet outlet connector c In the slot that s furthest from the thread we must place the O ring seal black on the inlet outlet connector d Insert the connector on the bypass s inl...

Страница 7: ...l over the floor To connect the overflow line connect a tube or hose with an interior diameter or 13mm and lead it to the drain we recommend a 17x13 transparent PVC flexible tube Always leave an air space between the drainage tube and the general drain to avoid the possibility of anything coming back up the drain This could affect the systems normal functionality 5 3 4 Connecting the inlet and out...

Страница 8: ...MING USER LEVEL INSTALLER Button Name Function SET CLOCK Set CLOCK Opens set the time mode NEXT NEXT Confiirm and move on REGEN REGEN Start regeneration Go back to the previous parameter UP DOWN ARROWS Increase or decrease the value Press The hour will flash Set the hour with the arrows Press The minutes will flash Set the minutes with the arrows Pressing again will take you to the service screen ...

Страница 9: ...ure there s water available 7 INSTALLATION CHECK LIST 8 START UP Installation Description Ok System positioning Hydraulic connections checked Inlet Outlet Bypass connected correctly and sealed tight Drainage connected correctly and sealed tight Brine connected correctly and sealed tight Overflow connected correctly and sealed tight Electric connection Programming carried out 8 1 Bleeding air Posit...

Страница 10: ...e apart and press tightly all of the suction line s components Open the valves and check to see if it s solved This step is extremely important to assure that the system works correctly Press for 5 seconds The softener will go into the BRINE UP cycle Check that the valve is pulling water from the deposit evenly without taking air in bubbles 8 3 Suction verification 8 3 1 Suction 8 3 2 Filling Chec...

Страница 11: ...urities that could damage your system This type of salt usually comes in 25kg bags The amount is irrelevant as long as you assure that there s enough salt to exceed the water level and thus guaranteeing brine saturation The amount needed to regenerate depends on the model and is related to the last table on system s technical data point 2 7 Characteristics in this manual We advise you to add more ...

Страница 12: ...dic checks The Kobe system is autonomic and the majority of the necessary actions for maintenance are carried out on its own Nonetheless there are some small tasks that we should verify periodically to make sure our system works correctly and is long lasting These are If the system is sat for a month or longer without use it must be disinfected using the product PQ 1602 10 Consult our Technical De...

Страница 13: ... Replace resin 12 2 Problems causes and possible solutions All of the procedures marked with the symbol involve decompressing the valve as follows Close the system s inlet valve Open the installation s lowest consumption point Press the button for 5 seconds Wait for the valve to finish positioning itself and press and release the to go to the BACKWASH cycle When it s fully positioned unplug the sy...

Страница 14: ...or bracket 4 AV 3020 08 1 CLACK electronic circuit 5 AV 3020 10 Optical gears reducers 6 AV 3020 12 1 CLACK gear assembly cover ID CODE DESCRIPTION 1 AV 3020 14 1 CLACK gaskets and separators set 2 AV 3020 16 1 CLACK shaft piston gear assembly 3 AV 3020 18 1 CLACK programming rear bracket 4 AV 3020 22 1 CLACK Counter current piston 5 AV 3020 24 Salt piston 6 AV 3020 26 228 O ring seal 7 AV 3020 28...

Страница 15: ...5 O ring cover 3 AV 3020 40 1 CLACK injector filter 4 AV 3020 42 1 CLACK injector plug 5 AV 3012 01 Black A injector ID CODE DESCRIPTION 1 AV 3020 48 1 CLACK refill plug 2 AV 3020 50 Elbow clip 3 AV 3020 52 3 8 CLACK tube support 4 AV 3020 54 3 8 suction elbow nut 5 AV 3020 56 3 8 suction elbow 6 AV 3020 58 019 O ring seal 7 AV 3020 60 1 CLACK refill 8 AV 3020 62 Refill rubber AV 3020 64 complete ...

Страница 16: ... elbow nut 4 AV 3020 66 1 CLACK drainage male elbow 5 AV 3020 58 019 O ring seal 6 AV 3020 68 DLFC set 7 AV 3012 14 Rubber flow regulator for 8 1 7 gpm Kobe 14 22 AV 3012 16 Rubber flow regulator for 10 2 7 gpm Kobe 35 AV 3020 70 complete drainage elbow kit ID CODE DESCRIPTION 1 AV 3020 78 1 QC drainage nut 2 AV 3020 80 Compete counter Includes no 3 4 3 AV 3020 82 1 CLACK counter turbine 4 AV 3020...

Страница 17: ...2 BP 0802 25 10X18 WOUND BOTTLE Kobe 14 2 AV 0202 12 35 100CM RESIN TUBE AND NOZZLE 3 AV 0202 16 1 268 EO1320 UPPER NOZZLE 4 VA 3002 06 CLACK WS1CI UF VOL VALVE 5 MD 3200 06 CLACK UPPER HOUSING BODY 6 MD 3200 04 10X35 CLACK LOWER HOUSING BODY Kobe 22 35 MD 3200 02 10X18 CLACK LOWER HOUSING BODY Kobe 14 7 MD H4850 34 Suction tube safety Buoy Chimney Kobe 22 35 MD H4850 17 Suction tube safety Buoy C...

Страница 18: ...iod of 2 years in accordance with the provisions of the Guarantees of Consumer Goods Law 23 2033 on 10th July 1 year in the case of products not covered by the aforementioned law The guarantee includes the repair or replacement of defective parts by authorized personnel THIS DOES NOT INCLUDE postage or travel expenses if necessary The replacement of parts subject to natural wear consumables lack o...

Страница 19: ...a Chirivella Aldaya 48 46960 Aldaya Valencia Spain Tel 34 961 98 62 30 hidrowater hidro water com www hidro water com MA EN DESCALCIFICADOR KOBE USR UF 3004 XX JD18V01 DISTRIBUTOR INSTALLER Sale date Instalation date Stamp Stamp ...

Отзывы: