6.4.1 Inlet hardness
6.4.2 Outlet hardness
6.4.3 Forced regeneration
6.4.4 Regeneration time
6.4.- Programming
Always starting from the service state, at the same time press + for 3 seconds
to enter the programming mode.
Set the hardness using
Press to confirm and move onto the next
parameter
Adjust residual hardness using , programme
to 90 ppm
Press to confirm and move onto the next
parameter
You can check in point
8.5.- Residual hardness setting,
in this manual, how to make the adjustment
residual hardness.
Adjust days using programme 7
Press to confirm and move onto the next
parameter
By default, the programmed regeneration time is 2:00 am as it’s a time when generally there won’t
be any water consumption and therefore there’ll be good pressure. If you want the regenerations
to be at a different time for whatever reason, programme the desired time in this parameter.
Adjust hour using
programme 2
Confirm using
Adjust minutes using
programme 00
Confirm using And we’ll be put back to the
service screen. The system has been programmed.
Once the valve has been programmed, it’s time to start up the system.
Make sure the softener’s inlet and outlet valve are
closed and that the bypass is open to make sure
there’s water available.
7.- INSTALLATION CHECK LIST
8.- START UP
Installation
Description
Ok?
System positioning
Hydraulic connections checked
Inlet-Outlet // Bypass connected correctly and
sealed tight
Drainage connected correctly and sealed tight
Brine connected correctly and sealed tight
Overflow connected correctly and sealed tight
Electric connection
Programming carried out
8.1.- Bleeding air
Position the valve in the
BACKWASH
position.
Press for 5 seconds The softener will go into the
BRINE UP
cycle. Wait until it is totally positioned (the motor
stops being heard and time starts to count down).
When the softener is totally positioned, press and release The softener will go into the
BACKWASH
cycle.
When it’s totally positioned, unplug the transformer from the electric supply.
½ open the bypass inlet valve and let the bottle fill slowly.
You’ll hear the air escaping down the drain. Keep it like this
until all of the air has been removed. You’ll know as now
water is being released into the drain and it doesn’t have
any bubbles.
If you open it too much or too fast, you can damage the system and /or lose resin.
In this position, you must listen to the air escaping slowly in the drainage line.
SOFTENER
SOFTENER
SOFTENER
SOFTENER
NEXT
NEXT
NEXT
NEXT
NEXT
NEXT
Introduce the hardness value of the water to be treated in PPM (mg/l CaCO3) (PPM= °F x 10)
Hidro-Water recommends leaving a residual hardness of between 80 and 100 PPM (mg/l CaCO3).
This is a safety measure to avoid water becoming stagnant for a prolonged period as this may
biologically contaminate the resins.