22
23
MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01
MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01
It’s recommendable to go through the resin cleaning process
when you set up the system and every 6 months with a sachet
of HW*77 resin cleaning product (PQ-1602-02). Only in the
event of not obtaining the hardness desired upon finishing the
procedure, a shock treatment would need to be carried out by
using 2 sachets.
The cleaning procedure is as follows:
• Empty the contents of a packet of HW*77 in the brine tank’s
chimney.
• Wait 2 hours for it to be completely dissolved.
• Carry out a complete regeneration.
The ways of carrying out a manual regeneration are:
• Immediate: Press and hold for 5 segundos.
• Delayed: Press and release (on the screen
REGEN TODAY
will start flashing) and
the system will regenerate at the next time that is programmed to do so. This option won’t
be available if the system is programmed as immediate regeneration.
9.- CLEANING
10.- MANUAL REGENERATION
11.- START-UP CHECK LIST
Id
Briev description
Ok?
1
Bleed air and rinse resin
2
Fill verification
3
Suction verification
4
Filling
5
Start-up
6
Adjust residual hardness
7
Add salt
8
Check flow meter
12.- MAINTENANCE GUIDE AND TROUBLESHOOTING
12.1.- Periodic checks
The
Kobe
system is autonomic and the majority of the necessary actions for maintenance are
carried out on its own.
Nonetheless, there are some small tasks that we should verify periodically to make sure our
system works correctly and is long-lasting. These are:
If the system is sat for a month or longer without use, it must be disinfected using the product PQ-1602-10. Consult
our Technical Department at Hidro-Water S.L.U.
PERIOD
CHECK
ACTION
15 days
Check the inlet filter
Check the dirt accumulated in the filter.
When it’s dirty, replace it if it’s
disposable cartridge or wash if washable.
1 month
Check the salt level
The softener only uses the salt it needs.
¡It doesn’t consume more just as it has more in its tank!
Check the salt periodically and fill with 25kg bags
of salt which is specially designed for softeners.
6 months
Resin disinfection
(Shock treatment is only required
when you can’t get the desired,
hardness after regenerating)
Preventive maintenance
Empty the contents of a sachet of the product
PQ-1602-10 in the brine tank.
Shock treatment
Empty the brine tank. Rinse the
tanks residue. Add 10L of water.
Add 2 sachets of the product PQ-1602-10 to
the tank and stir until perfectly dissolved.
Carry out a manual regeneration cycle.
1 year
Revisión Preventiva SAT
Process check and cleaning
of the valve’s internal parts.
REGEN
REGEN
CONGRATULATIONS! YOUR SYSTEM IS ALREADY FULLY INSTALLED AND RUNNING