INSTALLATION GUIDE
hidglobal.com
An ASSA ABLOY Group brand
© 2012 - 2018 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID GLOBAL, HID, the HID Brick logo, the Chain Design, and PIVCLASS are trademarks or registered
trademarks of HID Global, ASSA ABLOY AB, or its affiliate(s) in the U.S. and other countries and may not be used without permission. All other trademarks, service marks, and
product or service names are trademarks or registered trademarks of their respective owners.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
pivCLASS
R10-H, RP10-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P,
RPKCL40-P, RKCLB40-P
2
Wiring
Pigtail
Terminal
Description
Pigtail
Terminal
Description
Yellow
P1-1
Beeper Input
Red / Green
P2-7
*GPIO1/OSDP (RS485-FDX/HDX-A)
Orange
P1-2
LED Input (GRN)
Tan
P2-6
*GPIO2/OSDP (RS485-FDX/HDX-B)
Black
P1-3
Ground (RTN)
Violet
P2-5
**Open Collector Output / Tamper
Red
P1-4
+VDC
White
P2-4
***Wiegand Data 1 / Clock
Drain
P1-5
Unused
Green
P2-3
***Wiegand Data 0 / Data
Brown
P1-6
LED Input (RED)
Pink
P2-2
*GPIO3 (RS485-FDX-Z)
Blue
P1-7
Hold Input
Gray
P2-1
*GPIO4 (RS485-FDX-Y)
*RS-485 applicable for pivCLASS readers.
**Tamper Output - When activated, output synchronizes to ground (default).
***Dependent upon reader configuration. See the HTOG for Wiegand and Clock-in-Data configurations.
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
P1
P2
Beeper
GRN LE
D
GN
D
+VDC
DRAIN
RE
D
HOLD
GPIO
1
GP10
2
OC/TMP
R
DATA
1/CL
K
DATA
2/D
ATA
GPIO
3
GPIO
4
Beeper
GRN LED
GND
+VDC
DRAIN
RED
HOLD
GPIO1
GP102
OC/TMPR
DATA1/CLK
DATA2/DATA
GPIO3
GPIO4
18 in
(0.46 m)
BEEP (YEL)
GRN LED (ORN)
GND (BLK)
+VDC (RED)
DRAIN (BARE)
RED LED (BRN)
HOLD (BLU)
GPIO1(RED/GRN)
GPIO2 (TAN)
OC/TMPR (VIO)
DATA1 (WHT)
DATA2 (GRN)
GPIO3 (PINK)
GPIO4 (GRAY)
Terminal Reader
Pigtail Reader
(Terminal block and module
position varies)
(Module position varies)
Notes:
1. Previous iCLASS readers had reversed RS-485 wiring
(P2-7 & P2-6 - A & B). When upgrading to a pivCLASS
reader, ensure proper connections as defined below.
2. Wiring the reader incorrectly may permanently damage
the reader.
3. For cable lengths greater than 200 ft. (61 m) or EMF
interference, install 120Ω +/- 2Ω resistor across
RS-485 termination ends.
4. It is possible to reuse existing Wiegand wiring for
OSDP, however, using simple stranded cable (typical of
Wiegand access control readers) usually does not meet
RS-485 twisted pair recommendations.