Power & Testing
Contactless Models
Contact Models
Turn on power
Test card
Note:
With a keypad reader operating as 26 bit emulation, upon power up you have 5 seconds to enter the Facility Code followed by #.
If unsuccessful, the reader LED displays solid Red. Power-cycle the reader and retry entering the Facility Code.
The Facility Code needs to be manually entered as 3 digits (for example, if the Facility Code is 10, enter 0-1-0-#).
SE readers only use Facility Codes between 1-255. There is no default Facility Code.
Once the Facility Code has been entered, the LED will display Violet and then to a final Red. Then power-cycle the reader.
When using a keypad, if there are 2 short beeps after entering your PIN, the reader does not have a Facility Code configured yet.
In this event, an Administrator will need to power-cycle the reader and enter the Facility Code before the reader will accept your PIN.