Wiegand and OSDP Protocol

Installation

Mounting

Attach Backplate and Mounting Gasket to Junction Box.

Contactless Models                                                                             Contact Models

Communication protocols other than Wiegand 
or Clock & Data require an additional hardware 
module which increases current by 30 mA.

PRODUCT

BASE PART 

NUMBER

INPUT VOLTAGE 

(VDC)

CURRENT

1

OPERATING 

TEMPERATURE

CABLE LENGTH

5

UL REF 

NUMBER

Standby 

AVG

2

Maximum 

AVG

3

PEAK

4

R10-H

900N

5-16VDC

12VDC for RS-485

60mA

100mA

200mA

-30° to 150° F

(-35° to 65° C)

Communication Lines

Wiegand

 = 500 ft - 22 AWG

(152 m)

300 ft - 24 AWG

(91 m)

RS-485

 = Max. bus length 

4000 ft - 24 AWG

(1,219 m)

Max length between nodes: 

1,640 ft - 24 AWG (500m)

R10E

x

1

x

2

x

3

RP10-H

900P

75mA

RP10E

x

1

x

2

x

3

R40-H

920N

65mA

110mA

R40E

x

1

x

2

x

3

RP40-H

920P

85mA

RP40E

x

1

x

2

x

3

RK40-H

921N

85mA

125mA

220mA

RK40E

x

1

x

2

x

3

RPK40-H

921P

95mA

RPK40E

x

1

x

2

x

3

RKCL40-P

923N

12VDC

150mA

185mA

250mA

-4° to 122° F

(-20° to 50° C)

RKCL40E

x

1

x

2

x

3

RPKCL40-P

923P

RPKCL40E

x

1

x

2

x

3

UL Reference Number Deciphering

x

1

  Reader Colors:

  

K = Black

x

Wiring: 

  

N = Pigtail

 

                                              

T = Terminal

x

Communications:   N = No Module, 

 

                              R = RS-485 (OSDP)

Standby AVG - RMS current draw without a card in the RF field.

Maximum AVG - RMS current draw during continuous PIV card reads. 

 

Not evaluated by UL.

Peak - highest instantaneous current draw during RF communication.

Wiegand Cable Lengths:  100 ft (30.5 m) 22 AWG @ 5 - 6.4VDC

 

                                          500 ft (152 m) 22 AWG @ 6.5 - 16VDC

Junction box not included.

Mounting holes for US single-

gang electrical boxes.
Install gasket for RK40 and 

RPK40 models.

Mounting holes for US 

double-gang electrical 

boxes.

Reverse Configuration

   Rotating the backplate 

180° allows for placing the Contact reader on left 

and the Keypad reader on right.
See Section B Reconfigure Reader Assembly for 

instructions, before proceeding to Section 2.

Содержание pivCLASS R10-H

Страница 1: ...Order Guide Security tool for spanner security screw anti tamper HID 04 0001 03 Specifications pivCLASS Protocol PRODUCT BASE PART NUMBER INPUT VOLTAGE VDC CURRENT OPERATING TEMPERATURE CABLE LENGTH U...

Страница 2: ...ndby AVG2 Maximum AVG3 PEAK4 R10 H 900N 5 16VDC 12VDC for RS 485 60mA 100mA 200mA 30 to 150 F 35 to 65 C Communication Lines Wiegand 500 ft 22 AWG 152 m 300 ft 24 AWG 91 m RS 485 Max bus length 4000 f...

Страница 3: ...rown P1 6 LED Input RED Pink P2 2 GPIO3 RS485 FDX Z Blue P1 7 Hold Input Gray P2 1 GPIO4 RS485 FDX Y RS 485 applicable for pivCLASS readers Tamper Output When activated output synchronizes to ground d...

Страница 4: ...names are trademarks or registered trademarks of their respective owners This Installation Guide is for informational purposes only HID makes no warranties expressed or implied in this summary Company...

Страница 5: ...40 H RP40 H RK40 H RPK40 H RKCL40 P RPKCL40 P RKCLB40 P 4 Power Testing Contactless Models Contact Models Turn on power Test card Note With a keypad reader operating as 26 bit emulation upon power up...

Страница 6: ...in this summary Company product names and data used in sample output are fictitious Specifications are subject to change without notice pivCLASS R10 H RP10 H R40 H RP40 H RK40 H RPK40 H RKCL40 P RPKCL...

Страница 7: ...the left side of the assembly 1 Disassemble the reader Remove the Keypad reader from the backplate Carefully unplug the ribbon cable from the module in the back of the Keypad reader Caution Do not pu...

Страница 8: ...ith the M2000 pivCLASS Authentication Module as well as Standard Wiegand and OSDP panels FCC Certification CAUTION Any changes or modi cations to this device not explicitly approved by manufacturer co...

Отзывы: