background image

HID Corporation, 9292 Jeronimo Road, Irvine, CA 92618-1905, USA  •  Tel: (949) 598-1600, (800) 237-7769, Fax: (949) 598-1690 

http://www.hidcorp.com 

MaxiProx DFM Reader Installation Manual 5375-901 Rev D 

Page 

1 of 20

 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Installation Manual - 5375-901 Rev   D  
MaxiProx DFM Reader 5375A

 

 
 
 
 
 
 
 
 

Проектирование

Монтаж

Продажа

. - http://vskd.ru

Содержание MaxiProx 5375A

Страница 1: ...Irvine CA 92618 1905 USA Tel 949 598 1600 800 237 7769 Fax 949 598 1690 http www hidcorp com MaxiProx DFM Reader Installation Manual 5375 901 Rev D Page 1 of 20 Installation Manual 5375 901 Rev D Maxi...

Страница 2: ...WER SUPPLY 10 2 12 AUTOTUNE OPERATION 10 2 13 READER TESTING 10 2 14 POWER UP TUNE 10 2 15 PERIODIC AUTOTUNE 10 2 16 SUPERVISOR MODE 10 2 17 INSTALL COVER 10 CHAPTER 3 INSTALLATION NOTES AND GUIDELINE...

Страница 3: ...598 1690 http www hidcorp com MaxiProx DFM Reader Installation Manual 5375 901 Rev D Page 3 of 20 FIGURES FIGURE 1 MAXIPROX FRONT VIEW 11 FIGURE 2 MAXIPROX INTERIOR VIEW SHOWING MOUNTING HOLE LOCATIO...

Страница 4: ...ual 5375 901 Rev D Page 4 of 20 TABLES TABLE 1 TB1 CONNECTOR DEFINITION 7 TABLE 2 TB2 CONNECTOR DEFINITION 7 TABLE 3 DIPSWITCH AND JUMPER SETTINGS 8 TABLE 4 INTERFACE JUMPERS DESCRIPTION P3 AND P4 8 T...

Страница 5: ...Transponders Proximity Cards or ProxKeys are presented to the front of the MaxiProx The LED is red when ready to read a transponder The LED turns green and the beeper sounds when the transponder is r...

Страница 6: ...meter 40 inches to another MaxiProx 2 3 2 3 Mounting Applications Mounting Applications The MaxiProx may be mounted to a gooseneck that is 1 inch in diameter with a 4 inch diameter mounting flange wit...

Страница 7: ...ear of the MaxiProx Feed the cable through the cable fitting Connect the wires to the terminal strip with the minimum length necessary Do not leave extra loops of wire inside the Reader housing Connec...

Страница 8: ...sh after valid card read 6 Single Dual external LED Off Off single line LED control On dual line LED control 7 Serial Baud 1 control Off See baud rate chart below 8 Serial Baud 2 control Off See Baud...

Страница 9: ...e control line is necessary If ON it is in Dual Mode and the LED is normally off two control lines are necessary for host control of red and green 5 SW5 3 Terminating Resistor Some RS422 connections r...

Страница 10: ...e additional flash beep is the correct sequence for Green Flash Beep on valid read SW1 5 off Three initial green flashes and beeps followed by a pause and then one additional beep indicate no Green Fl...

Страница 11: ...onimo Road Irvine CA 92618 1905 USA Tel 949 598 1600 800 237 7769 Fax 949 598 1690 http www hidcorp com MaxiProx DFM Reader Installation Manual 5375 901 Rev D Page 11 of 20 Figure 1 MaxiProx Front Vie...

Страница 12: ...NT TB2 9 TX TB2 8 TX 1 3 P2 5 1 TB1 9 1 TB2 P1 1 3 P4 3 1 1 3 P3 SHUNT PINS 2 AND 3 21 28 5 VDC DEFAULT SHUNT PINS 1 AND 2 11 20 VDC SW1 SW2 SW5 SW5 1 SW5 2 SW5 3 SW5 4 SW5 5 SW5 6 SW5 7 SW5 8 DATA 1...

Страница 13: ...orbs energy from the Reader excite field and affects the signal being received from the card by re directing excite field transmissions into the receiver circuitry Moving the Reader away from the meta...

Страница 14: ...ess control cards 3 4 3 4 Transponder Types Transponder Types The type of transponder used affects the read range of the MaxiProx The various styles of HID cards and transponders use different types o...

Страница 15: ...s Code Format 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 P1 C C C C C C C C C C C C C C C C C C C C C C C C P2 Parity Format 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2...

Страница 16: ...Logic Levels Voltage Data Outputs Data0 and Data1 Control Inputs LED s Hold Beeper Levels Minimum Maximum Minimum Maximum Voh 3 5V 5 5V 3 5V 5 5V Vol 0 0V 0 5V 0 0V 0 5V Ioh 0 0mA 5 0mA 1 0mA 0 0mA I...

Страница 17: ...ed on Track 2 are 40 this product will output less than 40 characters The data consists only of BCD digits the remaining HEX digits A to F are used for the start and end sentinel data separators and c...

Страница 18: ...tripe card traveling at 8 9 inches per second The timing is to be adjustable for cards traveling at 4 inches per second to 20 inches per second This relates to bit times of 3 3 ms and 666us respective...

Страница 19: ...essage iiii LRC of nibbles aaaa to hhhh start B and end sentinel F xor of the nibbles or the even parity of the respective column The output from the Reader will look like the following 1248p 1248p 12...

Страница 20: ...ue 7 is sent as an ASCII character 7 or the hex value E is sent as an ASCII character E The CC field is reserved for use by HID Corporation The valid values are 00 through 7F The DDDDDDDDDD field is t...

Страница 21: ...ttp www hidcorp com MaxiProx DFM Reader Installation Manual 5375 901 Rev D Page 21 of 20 The checksum was computed by adding 00 01 23 4A BC DE 208 hex The checksum is the least significant 8 bits of t...

Отзывы: