35
Safety precautions and warnings
Operator's Manual GB
3.5.1
3.5.1 Preparations for use
DANGER
Ensure that there are no unauthorised persons
within the operating range of your crane!
TIP
Mark out the working range, e.g. with cones.
Put on your vehicle's warning lights.
DANGER
• If a part of the crane comes in contact with
an electricity line, you will be electro-
cuted!
• Maintain the following minimum distances
between the crane and overhead electricity
lines, unless otherwise prescribed by na-
tional rules.
Minimum distance between crane and over
head electricity lines
Voltage (V)
Minimum
distance to
an insulated
conductor
Minimum dis-
tance to an un-
insulated con-
ductor
<500 V
0.5 m
2 m
500-40000 V
1.5 m
4 m
>40000 V
2.0 m
6 m
Voltages are found:
up to 500 V:
to buildings
500-40000 V:
trams, trains
over 40000V:
power transmisson