JDC
48
The HiPro system
Operator's Manual GB
4.7.1
Power on/off
APO
Green light on: The system is on.
Green light blinking: System on and the stop button
has been pressed.
Green light flashing: APO emergency operation time
running.
Red light flashing: CAN communication has been
lost/ APO override time running
Stabiliser system
activation
Green light on: Stabiliser system active.
Green light flashing: Stabiliser extension is in locked
position.
OLP Release
Red light blinking: OLP Release active (crane, VSL
or stabiliser leg)
Green light flashing: Critical error.
Manual extensions
Green light on: Manual extension mode is active.
Remote control
Green light on: Remote control is active.
Green light flashing: Button for remote control has
been pressed, waiting for connection to hand unit.
Red light on: Radio interference.
Parking control
Blue light on: Slew is in parking position.
Service
Green light on: Service needed.
Red light on: Error in the system.
Red light blinking: Critical error.
Dump valve
Blue light on: Dump activated.
ADC
Blue light on: Crane has enhanced capacity (ADC
mode).
Hoist
Green light on: Hoist mode.
Red light flashing: 90% of OLP pressure.
Red light on: 100% of OLP pressure.
JDC
Blue light on: Outermost extension fully retracted
and the JIB has increased capacity (JDC mode).
VSL-OLP
Not active in this configuration.
Stabiliser legs
Not active in this configuration.
Stability sector
Green light on: regardless of the situation.