© 1995-2009 Energy Saving Products Ltd.
Service
The Hi-Velocity Air Purification System comes with a
built-in Remote Mounted Service Panel to automatically
keep track of service intervals.
(Fig. 11)
Indicator lights
will tell you when to change the filter and ultraviolet
lamps 30 days in advance.
MERV-13 Filter: Change every
6 months
- service light
turns from
green to yellow after five months and to red after six
months.
Ultraviolet Lamps: Change every
12 months
- service
light turns from green to yellow after eleven months and
to red after twelve months.
Operation
The Hi-Velocity Air Purification System installs in the
air-inlet side of the Hi-Velocity unit up to five tons in size.
Only operation of the air-handler fan unit is required for
air purification and sterilization to take place.
Note: The ultraviolet lamps are wired to operate
continuously. This feature allows the catalyst to burn off
surface impurities, cleaning and reactivating itself during
periods of non-use or no airflow.
Replacement Filters and Ultraviolet Lamps
Replacement components are available in the form of a
replacement kit containing (2) filters and (1) set of UV
lamps. Replacement kits are available from your local
HVAC wholesaler or contractor.
The HE PS System combines
three unique technologies
to protect people against indoor air pollutants.
Photocatalytic Oxidation (PCO)
technology combined
with high efficiency
electrostatic MERV-13 particulate
filtration
and
germicidal ultraviolet light
quickly
reduces and eliminates toxic gasphase chemicals, lung
damaging dust and airborne germs from the living
environment.
Many new homes have smart programmable thermostats
that allow for automatic operation of the air-handler
fan unit when there is no demand for heating or air
conditioning. It is important that the HE PS is operating
at least
(30) minutes per hour (24) hours per day
to
remove toxic materials from the indoor environment.
The length of operation depends on the location of the
home or office in relation to point source pollution such
as refineries, processing plants, automobile traffic and
areas that produce high levels of pollen. Individuals that
are sensitive to mold spores, dust mites, chemicals or
have respiratory problems such as asthma, emphysema,
and chronic allergies should extend the run time to (40)
minutes or more per hour.
Resetting Service Lights
On the right side of the service panel, there are arrows
pointing to two small holes marked reset. One is marked
filter and one is marked lamp
(Fig 11).
Using a small paper
clip, bend out one leg straight and insert the end of the
paper clip into only the hole corresponding to the replaced
component and push lightly until the service light returns
to the green position. The computer is now reset.
Fig. 11 Service Panel
PRESS HERE
TO RESET
(4)