© 1995-2009 Energy Saving Products Ltd.
Before installing the Hi-Velocity Air Purification System,
inspect for any signs of damage. During handling
and installation,
take care to protect the catalytic
honeycomb side
of the product from physical damage, as
the aluminum-titanium core is very soft and can be easily
damaged.
Warning -
Always
unplug the power cord from the HE
PS System when changing the filter or ultraviolet lamps.
Never
look into a burning ultravioletlamp without proper
eye protection as sever damage to the eyes can result.
This product is rated for standard ambient air temperatures
during heating and air-conditioning functions and not
rated for elevated air temperatures in excess of 125
degrees fahrenheit.
Do not
attempt to clean the catalytic honeycomb core
with cleaning solutions. The catalyst is radiated with short
wave ultraviolet light during periods of non-air flow and
is self-cleaning.
Do not
install insulation within 76MM or 3 inches of
Luminaries.
Access for service is required when mounting above
ceilings or behind walls.
Do not
install in a position where the
interior module can
gravity fall from an elevated position and cause injury to
people or equipment below.
(2)
Specifications
HE PS
HE PS-1750
Capacity
1.5-3 Tons
4-5 Tons
Dimensions
16
3/4
” W x 25” H x 10” D
21” W x 25” H x 10” D
Flange
1/2” around unit
Weight
23 lbs
26 lbs
Filter Size 15
7/8
” W x 24
3/4
” H x 3
3/4
” D
20
1/8”
W x 24
3/4
” H x 3
3/4
” D
Power
120v/54 watts/1.1amps
Fuse
AGC 2 amps
Service Panel
12 vac.
Catalyst
12,220 cells/4,583 Sq. In of Surface Area
Particle Filter
Electrostatic Needled MERV-13
Service
Filter - 6 Months *UV Lamps - 1 Year
Installation
Make sure to install the Hi-Velocity Air Purification System
so that the inlet or return air enters the side containing the
MERV particle filter first
(Fig. 1)
.
FILTER SIDE
CATALYST SIDE
AIR FLOW
Fig. 1 HE PS Air Flow
Typical Horizontal and Vertical
Installation
(Fig. 2, Fig. 3)
1.
Unscrew the two locking knobs and remove the
inside components from the outer case.
2.
Take care not to bend or distort the outer metal
enclosure.
3.
Mount the outer case to the support plenum Note:
Do not use a screw length that will extend into or penetrate
the inside module containing the catalyst or filter.
HE PS
RPM-E
Hi-Velocity Fan Coil
Air Flow
Fig. 2 Horizontal Installation
IMPORTANT SAFETY
INSTRUCTIONS
*Caution:
Risk of fire - replace only with 20180100001 U.V.
Lamps