Description 

 

1.1

 

General device description 

 
BN48-IP66 is designed for security, highway monitoring, industrial 
production control, and many other industries. The device meets the 
relevant industry standards, provides very high operational reliability, 
even under extreme conditions, and also long-term reliability and 
flexibility. 
 
The devices allow you to set up switched and routed industrial Ethernet 
networks that conform to the IEEE 802.3 standard. The devices work 
without a fan. 
 

There are convenient options for managing the device. 
Manage your devices via: 

  Web browser 

  Telnet(SSH) 

  Network management software (for example Industrial HiVision) 

  CONSOLE(RS232) interface (locally on the device) 

 
BN48-IP66 is a power sourcing equipment (PSE), Compatible with 
802.3at compliant Power Devices (PDs), With the presence of the PoE 
power supply, a separate power supply for the powered device is 
unnecessary. Support PoE management: 

  Power Management Mode 

  PD power detection and classification 

  PoE consumption limiting(Port power limit and Total power limit) 

  Detection for legacy PD devices 

  Port PoE Mode(PoE or PoE+) and Port PoE Priority 

 
 
 
 
 

 

Содержание BN48-IP66

Страница 1: ...Installation BN48 IP66 Release 01 11 2019 BN48 IP66 Managed Industrial Ethernet Switch Installation Manual ...

Страница 2: ... of the software for your own use The performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Shanghai HITE BELDEN Networking Technology Co Ltd Hi SCOM according to the best of the company s knowledge Hi SCOM reserves the right to change the contents of this document without prior notice Hi SCOM can give no gu...

Страница 3: ...2 Power supply state 10 1 5 3 Port state 10 1 5 4 PoE state 11 2 Installation 12 2 1 Checking the package contents 12 2 2 Installing and grounding the device 13 2 2 1 Installing the device 13 2 2 2 Grounding the device 13 2 3 Connecting the power supply 15 2 4 Operating the device 16 2 5 Connecting data cables 16 3 Switch Access 17 3 1 Access through Console Port 17 3 2 Access through Web 17 4 Res...

Страница 4: ...Hiscom product information including this manual Operate the product only according to the technical specifications See Technical data on page 20 Connect to the product only components suitable for the requirements of the specific application case Installation site requirements Install this device in an operating site with restricted access to which maintenance staff have exclusive access Device c...

Страница 5: ...ables Disconnect the grounding only after disconnecting all other cables Use toothed washers to ensure good electrical conductivity at the connection Requirements for connecting electrical wires Before connecting the electrical wires always verify that the requirements listed are complied with General requirements for connecting electrical wires The following requirements apply without restriction...

Страница 6: ...use interference in living areas and in this case the operator may be required to take appropriate measures LED or laser components LED or LASER components according to IEC 60825 1 2014 CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT Recycling note After usage this device must be disposed of properly as electronic waste in accordance with the current disposal regulations of your county state and country...

Страница 7: ...02 3 standard The devices work without a fan There are convenient options for managing the device Manage your devices via Web browser Telnet SSH Network management software for example Industrial HiVision CONSOLE RS232 interface locally on the device BN48 IP66 is a power sourcing equipment PSE Compatible with 802 3at compliant Power Devices PDs With the presence of the PoE power supply a separate ...

Страница 8: ...isplay elements for port status 4 LED display elements for power supply status 5 LED display elements for port status 6 LED display elements for PoE status 7 8 M23 RJ45 socket for 10 100 1000 Mbit s PoE port 8 Console 9 10 2 F O ports for 100 1000 Mbit s F O connections 11 Power supply 4 pin M12 A Code 12 Grounding Screw ...

Страница 9: ... 4 Management interface The CONSOLE RS232 interface is an RJ45 socket The CONOSLE RS232 user interface is serial and allows you to connect the following devices directly External management station PC with appropriate terminal emulation With this management station the Command Line Interface CLI is available to you Furthermore the system monitor is available to you at the system start Terminal Set...

Страница 10: ...ights up The device is normal None The device is failure 1 5 2 Power supply state This LED provides information on the status of the power supply LED Color Activity Meaning PWR Green Lights up The operating voltage is on None The operating voltage is off 1 5 3 Port state These LEDs provide port related information LS DA link status data Color Activity Meaning Green Lights up Device detects a valid...

Страница 11: ...N48 IP66 Release 01 11 2019 11 1 5 4 PoE state These LEDs provide information on the status of the PoE LED Color Activity Meaning Green Lights up The PoE power supply is active None The PoE power supply is inactive ...

Страница 12: ...subdomain follow these steps Checking the package contents Installing and grounding the device Installing an F O transceiver optional Connecting the power supply Operating the device 2 1 Checking the package contents Check whether the package includes all items below Number Article 1 Device 1 Installation Manual 1 Serial cable 1 A 4 pin M12 A Code for power supply Check the individual parts for tr...

Страница 13: ...les at the installation point Mount the device on a level surface with four M4 screws To preserve the suitability of your device for IP66 proceed as follows Remove the provided transport protection caps and the transport protection screws from the device Seal unused sockets and plugs with your desired type of protection screws 2 2 2 Grounding the device Grounding the device is by means of a separa...

Страница 14: ...Installation BN48 IP66 14 Release 01 11 2019 Note Ground the device before connecting any other cables Use toothed washers to ensure good electrical conductivity at the connection ...

Страница 15: ...nd do not touch the terminals Failure to follow these instructions can result in death serious injury or equipment damage A 4 pin M12 A Code is used for connecting the supply voltage Type of the voltages that can be connected Specification of the supply voltage Connections AC voltage Rated voltage range AC 176V 264V 50 Hz 60 Hz 1 L Outer conductor 2 PE Protective conductor 3 N Neutral conductor 4 ...

Страница 16: ...ength of the data cables as short as possible Use optical data cables for the data transmission between the buildings When using copper cables provide a sufficient separation between the power supply cables and the data cables Ideally install the cables in separate cable channels Verify that power supply cables and data cables do not run parallel over longer distances and that ideally they are ins...

Страница 17: ...t the COM port to be used Set the number of bits per second to 115200 the data bit is 8 the parity is none the stop bit is 1 the data flow control is none click the OK button to make it effective Successfully log in to the console interface of the device The default username admin and password admin 3 2 Access through Web Connect the network port of the PC to the RJ45 port of the switch with an RJ...

Страница 18: ...thin the first minute from switch reboot In the first minute after boot loopback packets will be transmitted at port 1 If a loopback packet is received at port 2 the switch will do a restore to default including the IP address The default IP address is 192 168 19 16 Proceed as follows Making a physical loopback between port 1 and port 2 Reboot the Switch ...

Страница 19: ...connect the grounding only after disconnecting all other cables Failure to follow these instructions can result in death serious injury or equipment damage Disconnect the data cables Disable the supply voltage Disconnect the power supply cables and signal lines Disconnect the grounding ...

Страница 20: ... V DC For the use of Type 2 Powered Devices PoE Rated voltage 54 V DC Max Voltage range 50 V DC 57 V DC Current consumption max 1 4 A 220 V AC Connection type M12 Shielded A Code PoE power BN48 0010O6O6TCMSB IP66 8 Powered Device PD class 4 30 W 8 Powered Device PD class 0 15 4 W Climatic conditions during operation Ambient air temperature2 40 C 55 C 40 F 131 F Humidity 10 95 non condensing Air pr...

Страница 21: ...InstallationBN48 IP66 Release 01 11 2019 21 Dimension drawings ...

Страница 22: ...rge 6 kV EN 61000 4 2 IEEE C37 90 3 Air discharge 8 kV Electromagnetic field EN 61000 4 3 80 MHz 6000 MHz 10 V m Fast transients burst EN 61000 4 4 Power 2 kV EN 61000 4 4 Signal 1 kV Voltage surges AC supply connection EN 61000 4 5 line earth 2 kV EN 61000 4 5 line line 1 kV Voltage surges data line EN 61000 4 5 line earth 1 kV Conducted disturbances EN 61000 4 6 150 kHz 80 MHz 10 V Network range...