background image

15

SPECIFICATIONS

SYSTEM

Operating range

100 ft (30 m) typical

Frequency range

311/315 MHz or 868/915MHz 

HF output power

2 - 3 mW

Operating 
temperature range

-25° to +70° C 

(-18° F to 158° F)

Enclosures

IP65 weatherproof (exceeds NEMA 
12/13)

Programmable

I/O Logic, Interlocking, Latching 
Functions

HH-M-MFSHL TS5 TRANSMITTER

Weight

1.1 lbs, 500g (includes battery)

Dimensions 

Height

Width

Depth

8.0 in (205 mm)

5.2 in(132 mm)

3.4 in (86 mm)

Power supply

2 - 1.5V ’AA’ batteries

Operation time

Up to 500 hours

Functions

E-Stop pushbutton
5 motion toggle switches
Proportional grey code trigger 
switch

Antenna

Internal

HH-M-MFSHL TS6P TRANSMITTER

Weight

1.1 lbs, 500g (includes battery)

Dimensions 

Height

Width

Depth

8.0 in (205 mm)

5.2 in(132 mm)

3.4 in (86 mm)

Power supply

2 - 1.5V ’AA’ batteries

Operation time

Up to 500 hours

Functions

E-Stop pushbutton
6 motion toggle switches
Proportional grey code trigger 
switch

Antenna

Internal

HH-L-MFSHL TS7P TRANSMITTER

Weight

1.3 lbs, 590g (includes battery)

Dimensions 

Height

Width

Depth

8.4 in (214 mm)

5.8 in(148 mm)

3.4 in (86 mm)

Power supply

2 - 1.5V ’AA’ batteries

Operation time

Up to 500 hours

Functions

E-Stop pushbutton
7 motion toggle switches
Proportional grey code trigger 
switch

Antenna

Internal

RX-MFSHL DC16-PWM RECEIVER

Operating power

12/24 VDC (+/- 20%)

Current

<100 mA

Safety features

Self-monitoring E-Stop circuits

Short circuit protection on ESTOP 
contact

Over-current protection (10A limit)

Equipped with solid state relays

Self-test during start-up and 
operation

On-board diagnostic system with 
indicators for RF communication, 
power status, active outputs

Outputs

16 solid state switching outputs
2 PWM outputs
1 Main Contact output

Antenna

Internal

PRELIMINAR

Y COPY

Содержание HH-L-MFSHL TS7P

Страница 1: ...r Avenue Halton Hills Ontario L7G 4X4 1 800 816 4459 Fax 1 905 702 0501 2005 Hetronic Inc All rights reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieva...

Страница 2: ...er 6 Receiver Housing 7 External Antenna Installation 7 Standard Antenna Extension 7 Top Mount Antenna Extension 7 Connect Electrical Wiring 8 Quick Disconnect Plug 8 Quick Disconnect Plug Wire Termin...

Страница 3: ...arising out of the use of unauthorized replacement parts BEFORE ATTEMPTING TO OPERATE THIS SYSTEM 1 Make sure all installation has been properly completed 2 Understand all safety precautions provided...

Страница 4: ...ess code This code allows the operation of multiple systems in the same general vicinity The receiver only accepts commands from the transmitter with the same address code MFS Transmission Technology...

Страница 5: ...pment PRACTICES AND LAWS Practice usual and customary safe working precautions for the benefit of yourself and others Understand and follow all safety messages Be alert to unsafe conditions and the po...

Страница 6: ...e gases or liquids Receiver must be protected from ambient temperatures outside the range of 18 to 158 F 25 to 75 C Receiver Production Number Locate the Hetronic Production number decal on the receiv...

Страница 7: ...g 4 Insert the mounting screws through the holes in the housing block and tighten into the mounting surface 5 Bundle any excess antenna cable and secure with tie wraps or equivalent IMPORTANT DO NOT r...

Страница 8: ...system using the new H Link wireless technology These are preset at the factory and are password protected Refer to the HH MFSHL H Link Programming Manual for more details IMPORTANT The Address and F...

Страница 9: ...P DK9 S0 S t o p S t o p DK1 DK2 DK3 DK4 DK5 DK6 DK7 DK8 DK9 DK10 DK11 DK12 DK13 DK14 S1 S2 S3 S4 S5 S6 S7 HH L MFSHL TS7P S t o p S t o p S0 TEST PROCEDURES WARNING FAILURE TO FOLLOW INSTRUCTIONS cou...

Страница 10: ...cates that the E Stop contact is open crane machine motions will NOT operate The LED on the receiver should flash yellow 5 Activate the motion toggle switches There should be NO movement of the crane...

Страница 11: ...that the transmitter batteries are fully charged and inserted into the transmitter handle If any control is NOT in the Off neutral position when the battery is inserted the transmitter will not turn...

Страница 12: ...a switch is active when the batteries are inserted the unit will go into an error state The red LED will come on and stay on until the active switch is turned off LED DESCRIPTION Transmit Mode Green...

Страница 13: ...sposed of with typical refuse Contact a professional hazardous waste disposal service MAINTENANCE WARNING The transmitter will switch to the EMERGENCY STOP condition after the set amount of time expir...

Страница 14: ...fter normal start up procedure E Stop switch engaged Pull out E Stop switch Batteries fully discharged Check batteries to ensure a full charge Replace with new batteries if necessary No power to the r...

Страница 15: ...AA batteries Operation time Up to 500 hours Functions E Stop pushbutton 6 motion toggle switches Proportional grey code trigger switch Antenna Internal HH L MFSHL TS7P TRANSMITTER Weight 1 3 lbs 590g...

Страница 16: ...operator is responsible for understanding and following all safety precautions in this and other applicable operator manuals INSTALLATION AND SAFETY TEST DATA Crane machine Data Manufacturer Model Num...

Страница 17: ...the crane machine controls Maintained control The function activates when the control is placed in the ON position The function stops when the control is placed in the OFF position Momentary control T...

Страница 18: ...c Millisecond MHz Megahertz MOV Metal Oxide Varistor type of surge suppressor mW Milliwatt NiCd Nickel Cadmium NiMH Nickel Metal Hydride PLC Programmable logic controller PLL Phased locked loop PTO Pr...

Страница 19: ...any Company supplied items or materials List prices or discounts are subject to change without notice Quoted prices will be honored for a period of 90 days from the date of the written quotation unles...

Отзывы: