78
-
Symptoms
Points to Check
Abnormal point cloud
(obviously misaligned
points, flashing
points, or incomplete
FOV)
Verify that:
·
Lidar's cover lens is clean. If not, refer to Chapter 6 (Sensor Maintenance) for the cleaning method;
·
Lidar's calibration file is imported, see
PandarView User Manual
(Use);
·
horizontal FOV is properly set on the Azimuth FOV page of web control;
·
motor's spin rate is steady on the Home page of web control;
·
Lidar's internal temperature is between -40℃ and 110℃ on the Operation Statistics page of web control.
Afterwards, check for packet loss:
·
If no packet is missing and yet the point cloud flashes, please update PandarView to the latest version (see the
Download page of Hesai's official website or contact Hesai technical support) and restart the PC.
If the point cloud is still abnormal:
·
try connecting the lidar to another PC;
·
power on again to check if the symptom persists.