Troubleshooting
In case the following procedures cannot solve the problem, please contact Hesai technical support.
Symptoms
Points to Check
Indicator light is off on
the connection box
Verify that:
·
power adapter is properly connected and in good condition;
·
connection box is intact;
·
input voltage and current satisfy the requirements in Section 2.3 (Connection Box).
Power on again to check if the symptom persists.
Motor is not running
Verify that:
·
power adapter is properly connected and in good condition;
·
if a connection box is used, the connection box is intact;
·
input voltage and current satisfy the requirements in Section 1.4 (Specifications) and 2.3 (Connection Box);
·
web control can be accessed (see "cannot open web control" on the next page);
·
the lidar is not in standby mode, see Section 4.2 (Web Control – Settings).
Power on again to check if the symptom persists.