76
-
Symptoms
Points to Check
Motor is running but
no output data is
received, neither on
Wireshark nor on
PandarView
Verify that:
·
Ethernet cable is properly connected (by unplugging and plugging again);
·
Lidar's Destination IP is correctly set on the Settings page of web control;
·
horizontal FOV is properly set on the Azimuth FOV page of web control;
·
firmware version of the sensor is correctly shown on the Upgrade page of web control;
·
Lidar is emitting laser light. This can be checked by using an infrared camera, an infrared sensor card, or a phone
camera without infrared filter.
If a connection box is used:
·
replace the current Ethernet cable with another cable of at least Cat 6; Cat 7 or higher is recommended.
Power on again to check if the symptom persists.
Can receive data on
Wireshark but not on
PandarView
Verify that:
·
Lidar Destination Port is correctly set on the Settings page of web control;
·
PC's firewall is disabled, or that PandarView is added to the firewall exceptions;
·
PC's VLAN ID is the same as the lidar's; (NOTE This requirement applies only when the product model supports
VLAN and that VLAN tagging is enabled.)
·
the latest version of PandarView is installed on the PC.
Power on again to check if the symptom persists.
Содержание QT128C2X
Страница 1: ...QT128C2X 128 Channel Short Range Mechanical Lidar User Manual HEVLWH...
Страница 18: ...16 2 Setup 2 1 Mechanical Installation Figure 2 1 Left View Unit mm...
Страница 19: ...17 Figure 2 2 Mounting Base Unit mm...
Страница 20: ...18 2 1 1 Recommended Installation Figure 2 3 Recommended Installation...
Страница 70: ...68 In case the following warnings appear select Trust this CA to identify websites...