1.3
Channel Distribution
The vertical resolution is
· 0.33° between Channel 6 and Channel 30
· 1° between Channel 5 and Channel 6, Channel 30 and Channel 38
· not evenly distributed in the remaining channels, as detailed in Appendix I
Figure 1.5 Channel Vertical Distribution
Figure 1.6 Laser Firing Position (Unit: mm)
Each channel has an intrinsic angle offset, both horizontally and vertically.
The offsetted angles are recorded in this LiDAR unit's angle correction file, which is provided
when shipping the unit.
In case you need to obtain the file again:
· Send this PTC command
PTC_COMMAND_GET_LIDAR_CALIBRATION
, as described in Hesai TCP API Protocol (Chapter 5).
· Or export the file using PandarView, see the PandarView user manual.
· Or contact a sales representative or technical support engineer from Hesai.