No. Fault report
Cause of fault
Fault correction
085
SUCTION MODE
Failure at pellet suction; fuel storage
room empty; misaligned vacutrans
flap; defect vacutrans flap sealing;
hose leakage; suction hose leaks or
is loose; suction turbine defect
Adjust suction cycles
Check discharge system (motor,
screw)
Check fuel quality
086
SUCTION VALVE
Empty level container at compact
container
Check vacutrans damper
Check end switch vacutrans damper
✆
- contracting party
087
ASH CONTAINER
Ash container door is opened
Connect ash container
Close ash container door
090
COMB. ROOM SENSOR
Burning chamber door end switch
active; burning chamber door is
open
Close burning chamber door
091
WARNING ASH
DISCHARGE
Ash discharge did not clean
respectively screw did not turn; ash
container full; debris block ash
screw; motor defect
Empty ash container
Remove debris
092
ERROR ASH
DISCHARGE
Ash discharge did not clean
repeatedly; ash container full; debris
block ash screw; motor defect
Empty ash container
Remove debris
✆
- contracting party
093
ENDSW. ROOM
DISCHARGE
Room discharge system end switch
active
Blockage; remove trapped fuel
Check fuel quality
Clean intermediate hopper level
sensor
094
AUTO. IGNITION
Fault automatic ignition
Check fuel quality
Use dry log wood
Clean burner plate holes
095
CHECK ASH BOX
Interval for checking the ash box is
exceeded
Check ash box and empty as
needed
096
BURNER STOP
Boiler operation mode „burner stop“
active
-
098
STACK
OVERFLOW
Stack Overflow
Buffer tank too small
Replace control
✆
- contracting party
099
WATCHDOG
WatchDog has released
✆
- contracting party