Description
of the menu navigation and adjustement values
6
23
Name
P56
Lambda control (Code protection)
Setting the Lambda control (Yes / No)
P57
Lambda probe (Code protection)
Display Lambda probe (0: Bistable probe / 1: Rolled wide strip probe)
P58
Rotation speed control (Code protection)
Display Rotation speed control inactive / active (0 / 1, 6, 11,12)
P59
Discharge (Code protection)
Display Discharge (0: Flexible Screw/ 1: Suction discharge / 2: Container)
P60
Ash discharge controlling (Code protection)
Display Ash discharge controlling active (Yes / No)
P61
Ash discharge interval (Code protection)
Setting Ash discharge interval (20-480min)
P62
Ash discharge duration (Code protection)
Setting Ash discharge duration (10-180sec)
P63
Lowburn time
Setting the Burn-out time (1-30min.)
P64
Pusher grate interval
Setting Pusher grate interval (5-600sec)
P65
Pusher grate duration
Setting Pusher grate time (1-60sec)
P66
Value reset (Code protection)
Display value reset (Yes / No)
P67
Service time reset (Code protection)
Display Service time reset (Yes / No)
P68
Boiler-type
Setting boiler-type (0-4)
P69
Brightness
Setting Brightness (10-99)
P70
Contrast
Setting Contrast (25-50)
By pressing the button:
"On/Off":
The equipment is switched on/off
„F1“:
(
T) changes to the „TIME-MODE“-menu
„F2“:
Scroll up
„F3“:
Scroll down
„F4“:
Value can be changed
PS 20
6
-
P56
P57
P58
P59
P60
Yes
0
0
2
No
T
20 %
F1
F2
F3
F4
Содержание pelletstar ECO 10
Страница 1: ...OPERATING INSTRUCTIONS Pellet boiler pelletstar ECO 10 60 ...