Fault reports and their correction
9
Betriebsanleitung_PS_10_60_Touch_Englisch_V1.3
87
9.1
Faults not indicated on the display (Maintenance)
Boiler output gradually
decreases
Ash/slag on the grate
Fly ash container full
Heat exchangers heavily clogged/
sooted up
Reduce cleaning intervals or
clean manually.
Empty the fly ash container.
Clean the heat exchangers.
Desired
operating
temperature
is
not
reached
Fuel of inferior quality.
Previous boiler output higher than
current boiler output
Fuel level too low
Replace fuel if necessary
Install a larger boiler
Increase fuel level
Ash is emitted from the
chimney
Fly ash container full
Fuel contains excessive fines or super
fines
Fan speeds too high
Chimney draught too high
Remove fly ash
Replace fuel if necessary or
retrofit flue gas deduster.
Reduce speeds
Retrofit chimney draught regulator