7
Description of the menu navigation system and settings
18
Betriebsanleitung_PS_10_60_Touch_Englisch_V1.3
7.3
Operation and handling
The touch panel is a touch-sensitive screen and a display and control unit. By touching the screen you can
change released values or move to other pages. The touching can be done with finger, pen, pencil, etc.
Figure 7.3: Operation of the screen with fingers or pen
NOTE: The values shown in the individual screenshots are not default values!
7.4
Explanation of the symbols
In this section important symbols are explained, which are displayed on the following menu pictures.
The
CHIMNEY SWEEPING FUNCTION
is available as a test mode for the chimney
sweeper. The boiler is precisely operated using rated output and the chimney sweeper can
carry out its test measurements. This condition is exited with deactivation or exceeding of
the boiler maximum temperature or where the maximum chimney sweeping time is
exceeded. All loads are set to the permissible maximum value. Any measurements should
only be carried out if the “
chimney sweeping mode
” appears on the display and an
appropriate flame has been formed. Otherwise there is no guarantee that the boiler will
demonstrate optimum combustion. It is possible that the boiler will only work in ignition or
burning phase.
By the
Aggregate-Test
the connected components can be tested individually
The symbol is only visible, when
the code has been entered (see chapter 7.5, page 19) and
the boiler is in the operating condition “Heating off” (only applies to the Agg-test for
the boiler!)
When the Aggregate-Test is active, the symbol turns green and the messag
e “AGG-Test
ACTIVE” is shown on the display area of the operating conditions.
Information’s
such as firmware-module, hardware-module, software version etc., of each
module (boiler, hot water tank, buffer, solar, heating circuit) are shown here.
These symbols (
navigation
) can be used to navigate between the pages in each module
(boiler, hot water tank, buffer, solar, heating circuit, hydr. compensator, net pump, zone
valve, ext. demand). An alternative to the illustrated method of navigation is the wiping to the
right or left on the screen.
Pressing this button returns you to the overview of the modules (boiler, hot water tank,
buffer, solar, heating circuit, hydr. compensator, net pump, zone valve, ext. demand).
Содержание pelletstar 10
Страница 1: ...Operating instructions pelletstar 10 60 ...
Страница 92: ...13 Notes 92 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 13 NOTES ...
Страница 93: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 93 ...
Страница 94: ...13 Notes 94 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 ...
Страница 95: ...Notes 13 Betriebsanleitung_PS_10_60_Touch_Englisch_V1 3 95 ...