Installation Requirments

07

IMPORTANT - PLEASE READ

This/these fitting/fittings needs/need to be 

installed in accordance with the following 

Installation Requirements and Notes (IRN) 
to ensure they meet the requirements of the 
Water Supply (Water Fittings) Regulations 

1999 and the Scottish Byelaws 2004.

IRN R001: Basin Taps, Bath Taps, Basin Mixer, 
Bath Filler, Bath Shower Mixer 
See text of entry for Installation Require-

ments or Notes.

IRN R005: Bath Filler, Bath Shower Mixer

This tap or combination tap assembly has 
a Type AUK2 air gap and is therefore only 
suitable for installation in domestic premis-
es or in other premises to protect against a 

backflow risk up to a Fluid Category 3, unless 

additional backflow protection for the higher 

risk is included in the installation.

IRN R006: Basin Taps, Bath Taps, Basin Mixer 
This tap or combination tap is installed so 

that its base is no lower than the spillover 
level of the receiving vessel (for example, a 
sink or washbasin), a Type AUK3 air gap is 
achieved which permits installation of the tap 

in any premises where backflow protection 

up to Fluid Category 5 is required at the tap.

IRN R010: Basin Mixer, Bath Filler 
Schedule 2-15 (1)
Water supplies shall be a reasonably balanced 

pressures from a common source (e.g. hot 
and cold supplies both from the same storage 

or both from a supply pipe). Where the fitting 

is supplied from unbalanced supplies (e.g. hot 

and cold supplies from separate sources) a 
‘Listed’ single check valve or some other no 

less effective backflow prevention device shall 

be fitted immediately upstream of both hot 

and cold water inlets.

IRN R030 – Bath Shower Mixer 

Schedule 2-15 (1) Multiple inlet fittings 

installed in domestic premises or in other 

premises to protect against a backflow risk 

up to a Fluid Category 3, incorporating a self 

cancelling diverter acceptable as a backflow 

prevention device (HC) and having an AUK2 

or AUK3 air gap, shall be installed in accord-

ance with IRN R010.

Multiple inlet fittings installed in premises 

other than domestic to protect against a 

backflow risk up to a Fluid Category 5, incor

-

porating a self cancelling diverter acceptable 

as a backflow prevention device (HC only) 

and having an AUK2 or AUK3 air gap, shall 
be installed in accordance with IRN R010. 

Alternatively the fitting shall be supplied in 

accordance with IRN R040 unless the show-
er head is constrained above the spill-over 
lever of the bath, wash basin or shower tray.

Содержание Lymington TLYCG00

Страница 1: ...ructions Lymington Range Models Covered TLYCG00 TLYCG01 TLYCG02 TLYCG04 TLYCG07 Please keep this booklet for future reference Installer When you have read these instructions please ensure you leave th...

Страница 2: ...These fitting instructions have been created to give you all of the information you need and if you need any further help please do not hesitate to give us a call on 0844 701 8503 Important Safety In...

Страница 3: ...ion Unplug equipment after use This product must not be modified in any way as this will invalidate the guarantee These fittings need to be installed in accordance with and meet the requirements of th...

Страница 4: ...Dimensions 04 Basin Taps Bath Taps G3 4...

Страница 5: ...Dimensions 05 Basin Mixer Bath Filler...

Страница 6: ...Dimensions Bath Shower Mixer 06...

Страница 7: ...d at the tap IRN R010 Basin Mixer Bath Filler Schedule 2 15 1 Water supplies shall be a reasonably balanced pressures from a common source e g hot and cold supplies both from the same storage or both...

Страница 8: ...the pre fitted threaded tails A suitable spanner may be required to fully tighten the backnuts 12 4 Connect the hot and cold water supplies to the taps 5 Turn on the water supplies and open both taps...

Страница 9: ...cold water supplies 5 Fit the clicker waste 11 to the basin ensuring a rubber washer is fitted between the basin and the waste Use a pure silicon sealant where necessary Place the other rubber washer...

Страница 10: ...onto the pre fitted threaded tails A suitable spanner maybe needed to fully tighten the backnuts 12 4 Connect the hot and cold water supplies using tap connectors not supplied 5 Turn the handles in bo...

Страница 11: ...se outlet using the small washer and the handset 16 to the hose using the small washer 6 Fit the wall bracket Not Shown to the wall using the fixings supplied ensuring the handset 16 and hose 15 reach...

Страница 12: ...d water areas combined with constant use eans you may need to clean your showerhead once a week To ensure continued performance the showerhead needs to be regularly descaled Maintenance 12 Shroud Valv...

Страница 13: ...grub screw and pull the handle upwards from the shroud 3 Unscrew the shroud remove the cartridge retaining nut and pull out the cartridge 4 Carefully clean the cartridge seals and seating 5 If necess...

Страница 14: ...soft water Hard Water Regions in England and Wales Soft to moderately soft 0 100mg l as calcium carbonate equiv alent Slightly hard to moderately hard 100 200mg l as calcium carbonate equivalent Hard...

Страница 15: ...ap has been turned off This is caused by capillary action and residual water in the spout being siphoned out This should only last for a couple of seconds Constant dripping leaking when the tap is not...

Страница 16: ...validate you guarantee To register simply go on line at www heritagebathrooms com register GuaranteeTerms and Conditions The guarantee is in addition to your statutory and other legal rights and is su...

Страница 17: ...onsequential loss of any kind In the interests of continuous product improvement Heritage reserves the right to alter product speci fications without notice Need help In the unlikely event that you en...

Страница 18: ...Notes Please use this space to add any notes you or your installer may have regarding plumbing system installation of this product 18...

Страница 19: ...19 Notes Please use this space to add any notes you or your installer may have regarding plumbing system installation of this product...

Страница 20: ...Heritage Bathrooms Birch Coppice Business Park Dordon Tamworth B78 1SG Website www heritagebathrooms com Telephone 0844 701 8503 Email technical heritagebathrooms com Lymington D1...

Отзывы: