background image

 
 

                                            

EN – Translation of the original user manual -  3.0 | 2018 

1.4

 

PRESCRIBED USE / APPLICATION 

 
Only the correct installation and maintenance by an authorised/qualified company 
or person in agreement with the user manual, logbook, checklists and maintenance 
lists can ensure the safe operation of the system.  
A qualified person is, according to EN 12635, a person who has the required train-
ing, qualified  
knowledge and practical experience required to install, test and maintain a  gate 
system correctly and safely. 
 
 
1.5

 

CONFORMITY WITH EUROPEAN DIRECTIVES 

 
The installation complies with the following EU Directives/ regulations: 
 

2006/42/  EC  Machine Directive 
2014/30  EU  EMC Directive (electromagnetic compati-

bility) 

305/2011  EC  Construction Product Regulation  

 
The design and production has been executed compliant with the applicable product 
standard EN 13241 and the underlying standards EN 12604, EN 12453, EN 12978 
and 12635.  
 
A Declaration of Performance (DoP) and Declaration of Conformity (DoC) are obliga-
tory for this product. The DoP and DoC are included in Appendix A.  
The CE mark is located on the left column of the gate. 
 

1.6

 

DELIVERY

 

 
The gate and the gate drive and control unit must be installed, connected, set up 
and tuned by a fitter or an engineer who also connects and programs any accesso-
ries. The gate control unit is adjusted to the options/accessories agreed with the 
user. The relevant options are laid down during hand-over. 
 
Of course, you can add optional/accessories afterwards. Contact your supplier for 
this. 
 
Gates are always delivered fully tested. 
 

 

Содержание sGate Trackless

Страница 1: ...8 User Manual sGate top guided sGate bottom guided sGate trackless Please read this original user manual before using this gate for the first time Act in accordance with the manual and keep it in a sa...

Страница 2: ...EN Translation of the original user manual 3 0 2018 2...

Страница 3: ...GENERAL SAFETY INSTRUCTIONS 9 2 4 SAFETY PROVISIONS EMPLOYED 10 2 5 INTENDED USE 10 2 6 SAFETY DURING USE 10 2 7 SAFETY DURING INSTALLATION MAINTENANCE AND DISASSEMBLY 11 OPERATION 12 3 3 1 OPENING C...

Страница 4: ...VAL 19 8 SPARE PARTS 20 9 TECHNICAL DATA 20 10 10 1 GATE DESCRIPTION 20 10 2 DRIVE DESCRIPTION 20 APPENDIX A DECLARATIONS DOP DOC 22 APPENDIX B OVERVIEW OF ERROR MESSAGES 24 APPENDIX C ELECTRIC DIAGRA...

Страница 5: ...ensure that you can continue to operate your gate problem free in the long term Please read this user manual carefully before using the gate Store the manual in a safe place to be able to refer to it...

Страница 6: ...77 Heras England Telephone 44 0 1302 364 551 Heras France Telephone 33 0 3 88 067 000 Heras Norway Telephone 47 22 900 555 Heras Sweden Telephone 46 0 77 1506050 1 3 DEFINITIONS USER OPERATOR ENGINEER...

Страница 7: ...omagnetic compati bility 305 2011 EC Construction Product Regulation The design and production has been executed compliant with the applicable product standard EN 13241 and the underlying standards EN...

Страница 8: ...ning it appears that the leakage current ex ceeds the permitted 3 5 mA an additional grounding in accordance with EN 60335 1 and IEC 30364 5 54 must be provided Measurement is made according to EN 603...

Страница 9: ...aults which might present a source of danger to the user or to third per sons must be eliminated immediately All warnings and safety notices on the equipment must be in place and clear ly legible at a...

Страница 10: ...is intended to control access to a specific plot premises or site The gate is intended for both industrial and private use The gate drive and control unit is adjusted to the options agreed with the u...

Страница 11: ...lock the gate The guide rail of the gate must always be free of snow ice or contami nants that may affect the sliding behaviour In the event of frost check this before commissioning the gate If the ru...

Страница 12: ...e gate closes completely STOP Press the Stop button The gate will stop immediately irrespective of its direction of travel To restart the gate press Open or Close 3 2 OPEN CLOSE MANUALLY In emergencie...

Страница 13: ...of the original user manual 3 0 2018 13 Remove the cord from the bracket and release it The motor brake is connected again and locks the gate Close the cover again The gate can once again be operated...

Страница 14: ...a width of approx 6 meters wide and a headroom of up to approx 4 meters Applications include port areas company buildings office buildings storage sites garden and landscape areas high risk sites air...

Страница 15: ...or passages with a width of up to approx 6 meters Applications include port areas company buildings office buildings storage sites garden and landscape areas high risk sites airports transport and dis...

Страница 16: ...s The type of device and the speed of movement depend on the motor control unit used If the safety device touches an obstacle the gate will immediately stop and reverse Dependent on the device the gat...

Страница 17: ...te will continue to open The closing movement will be stopped by the control when the trapezoidal loop is energised When the loop is released again the gate will close further The opening movement wil...

Страница 18: ...n emergency stop system can be connected to the control unit Please refer to the instruction in the installa tion manual MAINTENANCE INSTRUCTIONS 7 When working on the gate or cleaning it the power su...

Страница 19: ...joints damage to coating and zinc Check for damage and the operation of detection loops safety edges and photocells 7 2 CLEANING The gate and the outside of the drive unit cabinet can be cleaned using...

Страница 20: ...ON Type Top Guided Bottom Guided Clear pass m 4 0 6 0 3 0 6 0 Height m 2 0 4 0 2 0 2 5 Max weight kg 550 1100 3400 6000 Construction Guide rail at the top Guide rail at the bottom Type Trackless Clear...

Страница 21: ...A resp 690 W Maximum el motor power 750 W Housing material ABS plastic Dimensions W x H x D 182 x 328 x 102 mm incl spacers Weight approx 5 kilos IP category of control cabi IP54 Operating temperatur...

Страница 22: ...EN Translation of the original user manual 3 0 2018 22 Appendix A Declarations Dop DoC...

Страница 23: ...EN Translation of the original user manual 3 0 2018 23...

Страница 24: ...urrent motor has exceeded a set maxi mum running time The gate runs with difficulty or is ob structed If mechanical limit switches are used a limit switch may be defective If an encoder is used this f...

Страница 25: ...gency stop 1 Check external emergency stop wiring of 1 F212 External emergency stop 2 Check external emergency stop wiring of 2 F320 Gate blocked during opening The gate is stopped during opening F325...

Страница 26: ...switches both limit switches are activated at the same time F760 Gate position outside window range Incorrect operation of the drive of the po sition sensors Incorrect operation of the absolute en cod...

Страница 27: ...EN Translation of the original user manual 3 0 2018 27 Appendix C Electric diagram sGate universal...

Страница 28: ...EN Translation of the original user manual 3 0 2018 28...

Страница 29: ...EN Translation of the original user manual 3 0 2018 29...

Страница 30: ...EN Translation of the original user manual 3 0 2018 30...

Страница 31: ...EN Translation of the original user manual 3 0 2018 31...

Страница 32: ...EN Translation of the original user manual 3 0 2018 32...

Страница 33: ...EN Translation of the original user manual 3 0 2018 33...

Страница 34: ...EN Translation of the original user manual 3 0 2018 34...

Страница 35: ...EN Translation of the original user manual 3 0 2018 35...

Страница 36: ...EN Translation of the original user manual 3 0 2018 36...

Страница 37: ...EN Translation of the original user manual 3 0 2018 37...

Страница 38: ...EN Translation of the original user manual 3 0 2018 38...

Страница 39: ...EN Translation of the original user manual 3 0 2018 39...

Страница 40: ...EN Translation of the original user manual 3 0 2018 40...

Страница 41: ...EN Translation of the original user manual 3 0 2018 41...

Страница 42: ...EN Translation of the original user manual 3 0 2018 42...

Страница 43: ...EN Translation of the original user manual 3 0 2018 43...

Страница 44: ...EN Translation of the original user manual 3 0 2018 44...

Страница 45: ...EN Translation of the original user manual 3 0 2018 45...

Страница 46: ...EN Translation of the original user manual 3 0 2018 46...

Страница 47: ...EN Translation of the original user manual 3 0 2018 47...

Страница 48: ...EN Translation of the original user manual 3 0 2018 48...

Страница 49: ...EN Translation of the original user manual 3 0 2018 49...

Страница 50: ...EN Translation of the original user manual 3 0 2018 50...

Страница 51: ...EN Translation of the original user manual 3 0 2018 51...

Страница 52: ...EN Translation of the original user manual 3 0 2018 52 Appendix D Electric diagram sGate universal standalone...

Страница 53: ...EN Translation of the original user manual 3 0 2018 53...

Страница 54: ...EN Translation of the original user manual 3 0 2018 54...

Страница 55: ...EN Translation of the original user manual 3 0 2018 55...

Страница 56: ...EN Translation of the original user manual 3 0 2018 56...

Страница 57: ...EN Translation of the original user manual 3 0 2018 57...

Страница 58: ...EN Translation of the original user manual 3 0 2018 58...

Страница 59: ...EN Translation of the original user manual 3 0 2018 59...

Страница 60: ...EN Translation of the original user manual 3 0 2018 60...

Страница 61: ...EN Translation of the original user manual 3 0 2018 61...

Страница 62: ...EN Translation of the original user manual 3 0 2018 62...

Страница 63: ...EN Translation of the original user manual 3 0 2018 63...

Страница 64: ...EN Translation of the original user manual 3 0 2018 64...

Страница 65: ...EN Translation of the original user manual 3 0 2018 65...

Страница 66: ...Local supplier stamp...

Отзывы: