Reference temperature probe defect
Consequence:
The unit is out of order. The reference temp. probe on the keyboard pcb has broken.
Troubleshooting:
Change keyboard pcb.
Ice damage risk
Consequence:
The unit is out of order. A temperature of < 0°C (32°F) has measured on the keyboard pcb.
Position of the temperature probe:
The probe is located .
Troubleshooting:
Ensure that the temperature next to the unit is not less than < 0°C (32°F). Perhaps change oven
location.
Caution!
There is a high risk that water pressurized components were damaged.
13