Smart
Combi™
Service
Defect humidity sensor
Consequence:
The humidity function is deactivated.
Position of the humidity probe:
The probe is located at the fresh air pipe (behind the left side wall).
Designation of the component in the wiring diagram:
B5
Troubleshooting:
9
Check contacting at plug X11 on
the keyboard card A2 (also
between plug and cable). Reset
the electronic. Mistakes cleared?
No
Check occupancy of the probe at
plug X11 (see also wiring
diagram). Reset the electronic.
Mistakes cleared?
No
Change humidity probe.
Mistakes cleared?
Change keyboard card
No