42
8
8))
Hand-tighten compression nut and then a half turn with wrench.
NOTICE
Excess force will damage temperature probe.
9
9))
Locate temperature probe through pot wall.
1
10
0))
Place gauge against pot wall as shows in
Figure 6-1 Probe Assembly Install
1
11
1))
Push temperature probe through until it makes contact with gauge.
1
12
2))
Tighten temperature probe in place.
C
CA
AU
UT
TIIO
ON
N!! E
Exxcce
essss ffo
orrcce
e w
wiillll d
da
am
ma
ag
ge
e tte
em
mp
pe
erra
attu
urre
e p
prro
ob
be
e.. H
Ha
an
nd
d--ttiig
gh
htte
en
n n
nu
utt a
an
nd
d
tth
he
en
n 1
1//2
2 ttu
urrn
n w
wiitth
h a
a w
wrre
en
ncch
h..
1
13
3))
Connect new temperature probe to the connector and fasten connector onto
control panel.
1
14
4))
Replace control panel and reconnect power to vat.
1
15
5))
Fill vat by pressing and holding the filter button until *FILTER* *MENU* shows in
the display. Then once “1.EXPRESS FILTER” shows in the display, press ►4
times until “5.FILL FROM PAN” shows in the display. Press ✓ button and
“PUMP” “EXIT” shows in the display. Press √ button again, and oil fills vat. Once
vat is full, press X
X twice to return to normal operation.
Содержание Evolution Elite EEG-16 Series
Страница 2: ......
Страница 12: ...Preface x ...
Страница 18: ...Troubleshooting 6 ...
Страница 20: ...Information Filter Button Stats 8 ...
Страница 30: ...Product Program Mode 18 ...
Страница 92: ...Diagrams 80 8 8 2 2 W Wiir riin ng g D Diia ag gr ra am ms s ...
Страница 94: ...Diagrams 82 ...