![Henny Penny Evolution Elite EEG-16 Series Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/henny-penny/evolution-elite-eeg-16-series/evolution-elite-eeg-16-series_technical-manual_2124329025.webp)
13
Function
Display Example
Number of times oil discarded
(L/R) DISPOSE
1
Total number of cook cycles
(L/R) TOT CK
38
Number of cycles stopped before *DONE*
QUIT CK
2
Cook Cycles for Product #1
COOK -1-
17
Cook Cycles for Product #2
COOK -2-
9
Cook Cycles for Product #3
COOK -3-
5
Cook Cycles for Product #4
COOK -4-
0
Cook Cycles for Product #5
COOK -5-
0
Cook Cycles for Product #6
COOK -6-
6
Cook Cycles for Product #7
COOK -7-
0
Cook Cycles for Product #8
COOK -8-
0
Cook Cycles for Product #9
COOK -9-
1
Cook Cycles for Product #0
COOK -0-
0
R
Re
esse
ett u
ussa
ag
ge
e d
da
atta
a::
Enter the Usage Code - 1, 2, 3 on this step to
zero out all the usage information
RESET USAGE /
ENTER CODE
- - - - -
3
3..1
1..6
6 6
6.. IIn
np
pu
uttss
1
1))
Press the right arrow and “6. INPTS” and “HDF” show in displays.
H = HIGH LIMIT - If “H” is present, the high limit is good. If “-” shows then the
high limit is tripped out (overheated) or disconnected.
D = DRAIN SWITCH - If “D” is present, the drain handle (when applicable) is
closed. If “-” shows then the drain is open or the switch is faulty.
F = FAN (PRESSURE SWITCH) - If “F” is present, the pressure switch is good.
If “-” shows in the display, the switch is faulty.
2
2))
Press the down arrow and a “_” indicates the input is not presently detected. A ✓
indicates the signal is detecting a normal input. A blinking X
X indicates the signal
is presently detected, but is detected as a half-wave (partially failed) input.
NOTE: The H, D, F signals above are wired in series. The first signal missing out of
this sequence l generally causes all signals to the right of it to be missing as well.
3
3..1
1..7
7 7
7.. O
Ou
uttp
pu
uttss
1
1))
Press the right arrow and “7. OUTP” and “F-S-I-H-” show in displays.
F = FAN (PRESSURE SWITCH) - Press product button 1 or 6 to open and close
the pressure switches
S = SAFETY GAS VALVE (if available) - Press product button 2 or 7 to open
and close the gas safety valves.
Содержание Evolution Elite EEG-16 Series
Страница 2: ......
Страница 12: ...Preface x ...
Страница 18: ...Troubleshooting 6 ...
Страница 20: ...Information Filter Button Stats 8 ...
Страница 30: ...Product Program Mode 18 ...
Страница 92: ...Diagrams 80 8 8 2 2 W Wiir riin ng g D Diia ag gr ra am ms s ...
Страница 94: ...Diagrams 82 ...