![Henny Penny Chick-fil-A Controls 500 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/henny-penny/chick-fil-a-controls-500/chick-fil-a-controls-500_manual_2124317027.webp)
Henny Penny
Chick-fil-A Controls
Problem
Cause
Correction
PRESSURE SECTION (Continued)
Pressure does not
•
Not enough product in fryer
•
Place proper quantity of
build
or product not fresh.
fresh product within frypot to
generate steam.
•
Metal shipping spacer not
•
Remove shipping spacer.
removed from dead weight.
See Unpacking Section.
•
Lid open or not latched.
•
Close and latch lid.
•
Solenoid valve leaking or
•
Have solenoid valve checked or
not closing.
cleaned.
•
Dead weight valve leaking.
•
Have Dead weight valve
repaired.
•
Pressure not programmed.
•
See Diagnostic Mode
D 10
,
page 3-24. If pressure
settings have been changed,
have the controls reintialized..
•
Lid gasket leaking.
•
Reverse gasket or lid needs
adjusted.
•
Safety relief valve leaking.
•
Check and replace if necessary.
FILTER SYSTEM SECTION
Filter motor runs
• Pump clogged
• Have pump cleaned.
but pumps peanut oil
slowly
• Filter line connection
• Tighten all filter line
loose.
connections.
• Solidified peanut oil
• Clear all filter lines of solidified
in lines
peanut oil.
Filter switch on,
• Defective Cook/ Pump switch
• Have switch checked.
motor does not run
• Defective motor
• Have motor checked.
• Motor thermal protector tripped
• Reset thermal protector.