Henny Penny Chick-fil-A Controls 500 Скачать руководство пользователя страница 14

Henny Penny

     Chick-fil-A Controls

2-4.    WARNINGS AND
          ERROR MESSAGES
          (Continued)

ERROR  CODES

DISPLAY

CAUSE

CORRECTION

(500 fryer only)

“E-26”

Faulty contactors or PC board.

Have the contactors and PC board checked.

“HEAT AMPS

ARE

LOCKED ON”

This error code could be displayed even with
the Cook/Pump switch turned OFF.  Unplug
fryer or shut off the wall circuit breaker to
disconnect electrical power to fryer.

“E-41”

Memory scrambled.  An individual

Turn the Cook/Pump switch OFF and back to

“SYSTEM

product program may be scrambled.

COOK.  If error code persists, have the PC

DATA LOST”

Ex:  “E-41 -2-  DATA LOST”.  This

board checked or re-initialized.

means product #2 program is
scrambled.

“E-46”

Faulty eprom or PC board.

Turn the Cook/Pump switch OFF and back to

“DATA SAVE

COOK.  If error code persists, have the PC

FAILED”

board checked or re-initialized.

“E-70”

Faulty Cook/Pump switch

Have Cook/Pump switch checked, along with

“PWR SW

or switch wiring.  Faulty

its wiring.  Have I/O board checked.

OR WIRES

I/O board.

FAILED”

“E-92”

Blown 24 volt controller fuse, or

Have the 14-pin cable connector checked or

“24 VOLT

bad 14-pin cable connection.

have the fryer checked for a short to ground in

FUSE”

components such as the drain switch, solenoid,
or high limit.

Stuck or clogged solenoid valve.

Have solenoid checked and cleaned.

2-10

                602

Содержание Chick-fil-A Controls 500

Страница 1: ...Henny Penny Chick fil A Controls...

Страница 2: ...Henny Penny Chick fil A Controls...

Страница 3: ...Set 2 3 2 3 DiagnosticModeandSpecialFunctions 2 5 2 4 Warnings and Error Messages 2 8 2 5 BasicOperations 2 11 2 6 Clean Out Mode 2 16 2 7 Manually Setting New or Used Peanut Oil 2 17 2 8 CheckingTem...

Страница 4: ...ance See section 2 4 Alarms and Error Messages provide immediate feedback for Operator error or fryer malfunction See section 2 5 Status Mode allows the Operator to view basic fryer informa tion and s...

Страница 5: ...cooked 2 2 6 Press to display current fryer information and status If pressed in the Program Mode shows previous settings Pressing this along with accesses the Information Mode which has historicinfor...

Страница 6: ...stics the Clean Out Mode and toggles between English and Spanish display Press before entering any of the above modes 2 2 12 Cook Pump Switch A3 way switch with a center OFF position Turn the switch t...

Страница 7: ...y shows CS 1 then SET then MONTH withthe monthflashing 5 Press to change the month 6 Press Display shows CS 2 then SET then DATE withthe dateflashing 7 Press to change the date 8 Press Display shows C...

Страница 8: ...owing a 1 OFF No automatic adjustments for Daylight Savings Time b 2 US AutomaticallyappliesUnitedStatesDaylightSavings Timeadjustment DSTactivatedonthefirstSundayinApril DST de activated on the last...

Страница 9: ...ables changed by Operator On several of the screens you may have to press or to respond to questions asked Press at any time to exit and return to normal operation See section 5 3 for more details of...

Страница 10: ...cycle d The rate of temperature rise or fall e DateandTime Pressing during a cook cycle allows the Operator to view a The temperature of peanut oil plus the degrees and rate the Load Compensation has...

Страница 11: ...DATA information on the last cook cycle 5 TODAY S DATA data since the start of day not including the last cook cycle 6 PREV DAY SUN creates a log of the last 7 days using the informationinTODAY SDATA...

Страница 12: ...ait until peanut oil is at proper temperature WAS NOT before lights before loading product READY W 4 Frozen or too much product Do not overfill or place frozen product SLOW infrypot intothefrypot COOK...

Страница 13: ...d connection FRYER connection checked TEMP SENSOR FAILED E 10 Peanut oil temperature too hot Resethighlimit Checkpeanutoiltemperature HIGHLIMIT drain valve opened while heat was for overheating Have h...

Страница 14: ...ts have the PC DATALOST Ex E 41 2 DATALOST This board checked or re initialized means product 2 program is scrambled E 46 Faulty eprom or PC board Turn the Cook Pump switch OFF and back to DATASAVE CO...

Страница 15: ...owing prompts on the display or see section 3 3 for help Then display asks if the peanut oil is NEW or OLD The controls auto matically adjust the peanut oil temperature to the age of the pea nut oil U...

Страница 16: ...ing that the peanut oil is at the correct cooking temperature for the type of product being cooked The actual temperature may vary 20 degrees or more depending peanut oil age product weights product t...

Страница 17: ...Installation and Opera tion procedures 17 Near the end of the cook cycle the fryer automatically depressur izes Then at the end of the cook cycle an alarm sounds and the display flashes DONE Press to...

Страница 18: ...ode when FILTER SUGGESTED shows in the display the operator has the option to filter at this time or to continue cooking But if the operator continues cooking a Filter Lockout occurs within the next c...

Страница 19: ...de The fryer displays CLEAN OUT MODE and heats up to apreprogrammedtemperature thenautomaticallybeginsa15 minute timed countdown Use if necessary to adjust the temperature andkeepthecleaningsolutionfr...

Страница 20: ...controls resumenormaloperation 1 Heatpeanutoilandstircompletelyuntilpeanutoiltemperature has stabilized and is on 2 Place and electronic thermometer about 3 inches below the peanut oil s surface in t...

Страница 21: ...lows 1 Clearly define the problem or symptom and when it occurs 2 LocatetheproblemintheTroubleshootingtable 3 Review all possible causes Then one at a time work throughthelistofcorrectionsuntiltheprob...

Страница 22: ...oduct button pressed Be sure to press the correct product button If the fryer hasn t been used since the problem batch see Information Mode 4 B page 5 27 to see what product button was pressed B Too D...

Страница 23: ...If less than 5 off see Diagnos tic Mode D 1 page 5 11 b If between 5 and 15 degrees off calibrate probe If more than 15 degrees off replace probe Oil usage wasn t set for new See Diagnostic Mode D 2...

Страница 24: ...he product Done alarm ignored for more than 20 seconds If the fryer hasn t been used since the problem batch see Information Mode 4 H page 3 27 For more information on this prob lem see Information Mo...

Страница 25: ...e 5 24 If temperature settings have been changed have the controls reintialized Temperature probe out of Check temperature probe calibration calibration See section 4 6 a If less than 5 off see Diagno...

Страница 26: ...gged frypot have all pressure lines exhaust stacks and exhaust tank cleaned Solenoid valve clogged Have solenoid checked and cleaned Operating pressure too high Dead weight clogged Turn unit off and a...

Страница 27: ...ave Dead weight valve repaired Pressure not programmed See Diagnostic Mode D 10 page 3 24 If pressure settings have been changed have the controls reintialized Lid gasket leaking Reverse gasket or lid...

Страница 28: ...ked Faultyortrippedhighlimit E10 Resethighlimitpersection3 1 If high doesn t reset have it checked Drain valve open E15 Closedrainvalve Possible faulty probe E6 Have temperature probe checked Possible...

Страница 29: ...t day s voltage and heating performance Or see Information Modes 4 5 6 7 8 9 and 15 for more information on this problem pages 5 27 to 5 32 and 5 35 Weak or burnt out See Diagnostic Modes D 4 elements...

Страница 30: ...bouttheperformanceofthelinevoltagesupply Accessing Diagnostic Mode To activate Diagnostic Mode press the button then press button Thecontrollerdisplaysthefollowingmessage DIAGNOSTIC REPORT Whenthisint...

Страница 31: ...t position and are used to adjust the darkness setting To make the product darker press to move the blinking toward the DK darker side To make the product lighter press to move the blinking toward the...

Страница 32: ...s to move on to the second step This step shows the age of the peanut oil by percentage of its expected lifetime The peanut oil s present accumulated wear is compared to the wear setting at which the...

Страница 33: ...e end of each cook cycle for which low voltage has been detected While not cooking the Low Voltage alarm can sound as frequently as every 30 minutes around a value such as 90 means this value is progr...

Страница 34: ...anut Oil This report for the present batch of oil does not include data from the today It includes data for all days on the present batch of oil before today For example if Low Voltage warnings starte...

Страница 35: ...nd determines whether or not the heating system is operating normally The Heat Capacity is said to be bad only if the most recent heat up failed to meet the expected heat up rate and three of the last...

Страница 36: ...NE Otherwise if the Heat Capacity is presently assessed as bad or presently assessed as good but two or more heat ups today have not reached the expected heat up rate the following report sequence is...

Страница 37: ...k time will be longer than normal If the actual cook time stretches beyond a programmed limit the controller counts a SLOW COOK event and sounds an alarm at the end of the cook cycle If low voltage or...

Страница 38: ...ed to user error cooking too much product in one load cooking frozen product in the pressure fryer when it should be fresh or cooking before the Ready lightilluminates etc An individual XXXXX IS COOKI...

Страница 39: ...drop out of the Ready range by the time the user finishes loading closes the lid and starts the cook timer This is normal acceptable operation The controller accepts a cook cycle as ready if the peanu...

Страница 40: ...wn to 0 00 and the DONE indication was given This is strictly a user error Cycles that are canceled after cooking for less than 30 seconds are not counted here For example if a cycle is accidentally s...

Страница 41: ...Report Diagnostic Report section 8 reveals how many cook cycles beeped DONE for more than 20 seconds before the user pressed the Timer button to stop the cycle This is strictly a user error The contr...

Страница 42: ...presses the button to start a cook cycle the controller checks to see if any sudden change was observed prior to the start of the cycle If a sudden temperature drop was noted in the 90 second period...

Страница 43: ...layed D9 IRREGULAR D9 LOADING D9 FOR 8 OF D9 FILET Product Name D9 TODAY Loading Report for Present Batch of Peanut oil The data for this batch of peanut oil does not yet include cook cycles fromtoday...

Страница 44: ...program modes the controller either reports that allsettingsmatchoriginalvalues orreports Nitemsdonotmatch original values This report makes it easy to see if any cook parameters or other settings hav...

Страница 45: ...alwithspecialChick fil A controller features like OilWear Heat up Monitoring New Oil Compensation Oil Idle Compensation Drop Detection Clean out Mode andAmps andVoltage alarms If all items in CFAProg...

Страница 46: ...t Information Mode at any time or after 2 minutes controls automatically exit back to normal operation 1 E LOG error code log Press and 1A date time NOW shows in display This is the present date and t...

Страница 47: ...TA Press to step through the following data FUNCTION DISPLAYEXAMPLE Time of day the last cook cycle was started 4A STARTED 10 25A Product Last product cooked 4B PRODUCT 1 Ready Was fryer Ready before...

Страница 48: ...y when fryer on 5K MIN VOLT 95 No of Low Voltage warnings generated 5L LO VOLT S 0 Maximum Amp Draw today 5M MAX AMPS 35 Minimum Amp Draw today 5N MIN AMPS 33 Number of Low Amps warnings today 5O LO A...

Страница 49: ...J MAX VOLT 102 Minimum voltage that day when fryer on 6K MIN VOLT 98 No of Low Voltage warnings generated 6L LO VOLT S 0 Maximum Amp Draw that day 6M MAX AMPS 35 Minimum Amp Draw that day 6N MIN AMPS...

Страница 50: ...mp Draw 7J MAX AMPS 35 MinimumAmp Draw 7K MIN AMPS 32 Number of Low Amps warnings 7L LO AMP S 0 Non cooking time hrs while fryer was on 7M IDLE HRS 43 Total Oil Wear accumulated 7N TOT WEAR 278 Total...

Страница 51: ...VOLT S 0 Maximum Amp Draw 8J MAX AMPS 35 MinimumAmp Draw 8K MIN AMPS 32 No of Low Amps warnings 8L LO AMP S 0 Non cooking time hrs while fryer was on 8M IDLE HRS 43 Total Oil Wear accumulated 8N TOT W...

Страница 52: ...LO VOLT S 0 Maximum Amp Draw 9J MAX AMPS 35 MinimumAmp Draw 9K MIN AMPS 33 Number of Low Amps warnings 9L LO AMP S 0 Non cooking time hours while fryer was on 9M IDLE HRS 62 Total Oil Wear accumulate...

Страница 53: ...resent the drain handle is closed If D ismissing thedrainisopenorfaulty S Cook Pump switch on interlock circuit If S is present the Cook Pump switch is in the COOK position If the S is missing the pow...

Страница 54: ...ndisplay withthe flashing Press to view the amps status of each output H and P in the display means the amps are good Aflashing X behind the H or P means a problem exists Press to view the No Connect...

Страница 55: ...owupinthisdisplay Thevoltageisnormallydisplayedasa percentofnominal value where100 wouldindicatethatvoltageisrightonthenominalvalue i e 208 volts for a 208v fryer The display can be toggled to an actu...

Страница 56: ...use such as heating of the frypot without shortening 0 TO 3 YEARS During this time any frypot that fails due to manufacturing or workmanship is sues will be replaced at no charge for parts labor or fr...