3. START UP

3.1 Pre-start up checklist

 Eco Speed setting is compatible with  

other pool equipment 

 The pump is installed in a safe and dry environment 

  The pump enclosure has adequate drainage  

in the event of leakage 

 Any transport plugs are removed 

 The pipework is correctly sealed and supported

 The power supply is correctly connected 

 The pump is primed correctly 

 All steps have been taken for safe operation 

 The filter has been plumbed with 40/50mm pipe 

 

To realise the best energy efficiency from your pump, 
please follow these installation recommendations: 
•  Suction pipe length should be kept as short as possible 
•   Install a 450mm long straight pipe horizontally into the 

front of the pump

•  Minimise the number of bends in the plumbing

3.2 Starting the Pump

To operate efficiently and prevent pump damage there 
must be a free flow of water to and from the pump. Before 
starting ensure that:
•  All pipework is correctly sealed
•   The pool/spa water level is at the correct height (at least 

halfway up the skimmer base)

•   All appropriate valves are open and there is nothing 

preventing the flow of water through the system

The Henden 2 Speed Pump motor has 2 pre-set speed 
settings: Eco Flow and High Flow. 
1.  First prime the pump by removing the strainer basket lid 

and filling the strainer basket area with water. Replace 
the lid, ensuring that it seals on the large o-ring.

2.  Ensure the speed switch located on the motor is 

set to High Flow.

3.  Connect to the power supply and switch on.
4.  Allow the pump to run, so that any air trapped 

may be expelled.

5.  If prime is not established within approximately two 

minutes, as evidenced by a strong flow of water and no 
bubbles returning to the pool, switch off the pump and 
repeat the procedure. Continued evidence of air under 
the strainer basket lid indicates an air leak in the suction 
piping which should be rectified to avoid pump damage.

For optimum pump performance, the strainer basket 
housing should always be full of water and free from air 
bubbles. The water level of the pool should always be 
maintained to at least halfway up the skimmer box, which 
will ensure water is supplied to the pump at all times. From 
time to time it may be necessary to re-prime the pump. 
This should be carried out as described above.

Never run the pump dry. Running the 
pump with no water may damage the 
mechanical seals, causing leakage 
and flooding. Dry running damage 
and associated damage is not covered 
under warranty.

6

 

|

 

HENDEN

 INSTALLATION & OWNERS MANUAL

Содержание H62SP

Страница 1: ...re to follow these instructions and comply with all applicable codes may cause serious bodily injury and or property damage The installation of this product should be carried out by a person knowledge...

Страница 2: ......

Страница 3: ...STARTING UP 6 3 1 Pre start up Checklist 6 3 2 Starting the Pump 6 4 LOW ENERGY OPERATION 7 4 1 Using your Henden 2 Speed pump with a Henden Salt Water Chlorinator 7 4 2 Operating your automatic pool...

Страница 4: ...e ventilated to prevent condensation build up and allow a free flow of air for the fan cooled motor 1 3 Power Connection The Henden 2 Speed Pump is suitable for connection to a nominal 220 240 volt 50...

Страница 5: ...filter usually at the filter control valve Barrel unions need to be hand tightened No sealant glues or silicones are required ELECTRICAL DATA Model H62SP RPM Eco Flow Speed 1450 High Flow Speed 2850 E...

Страница 6: ...tem The Henden 2 Speed Pump motor has 2 pre set speed settings Eco Flow and High Flow 1 First prime the pump by removing the strainer basket lid and filling the strainer basket area with water Replace...

Страница 7: ...are using this pump with a Henden Chlorinator please ensure the flow rate is sufficient to cover your cell plates completely at all times of operation For other chlorinators please refer to the releva...

Страница 8: ...supply switch 2 Automatic overload is tripped The pump has an in built thermal overload which will re set automatically after the motor has cooled following an overheating period Determine the cause o...

Страница 9: ...Speed Pump be certain to quote the model number from the nameplate located on the motor NOTE If the pump is wired into a time clock or another automatic control the wiring should be removed by a qual...

Страница 10: ...WIRING MUST BE CARRIED OUT BY AN AUTHORISED ELECTRICIAN 10 HENDEN INSTALLATION OWNERS MANUAL 7 ROUTINE MAINTENANCE TASKS To maximise the life of your pool equipment personal safety use this checklist...

Страница 11: ...designed or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high vo...

Страница 12: ...P N 403749...

Отзывы: