Quick Installation Guide
Document
WERA4-Quick-US-200917
Page 19 of 73
4.16 Block Diagrams and Table of Interconnecting Cable
Cable Id Quant. Connect to Connect to
Description
1511
1
1.21
3.2
PA Control (15 poles male-female)
310
1
Line
UPS
AC Power of the whole WERA System
1511
1 (2)
2.7
3.7/8
Status control RER
1653
1
UPS
3.4
AC power cable 1 m for FCR
1653
1 (2)
2.6
3.4
AC power cable 1 m for RER
1938
1 (2)
1.20
2.2
RER Control (9 poles male-female)
1965
1
1.17
keyboard
Y-cable for keyboard and mouse
2173
1
1.25
Interface PC
Ethernet, cross-over
2528
3
AC input
3.4
AC power cable 1,8 m, FCR, PA, Monitor
2528
1
PC
UPS
AC power cable 1.8 m, monitor & PC
2870
1
SYNC
SYNC-Ant
PS2/RS232 special cable
9100
4 to 12
RF
RIN
RF cables to lightning protection, 3 m
3325
1
UPS
Interface PC
RS232 special cable
9007
1 (2)
1.23
2.4
Local oscillator signal to RER
With one RER only, 50 Ohms at 1.23
9139
1
2.3
4.12
Internal Cal. signal to Cal-Splitter
9155
1
2.4
4.12
20 V to Cal-Splitter
9008
1
1.1.1
1.5.1
Clock signal
9008
1
1.1.2
1.5.2
Trigger signal
9014
1
4.3
4.6.8
PA RF in to board (in-side PA)
9025
1
Line
4.4
AC Power PA (out-door version only)
4 to 12
2.1.2
1.6.1
to 1.6.4
Analog data signal, REC to ADC
1 pig-tail cable at each receiver
9034
1
2.1.2
Scope
Test cable Receiver to Oscilloscope
9058
1
1.16
1.19
Digital i/o port (DIO)
9073
1
PC-LPT
3.9
LPT cable, 1.8 m
9117
1
Test - Out
Cal-Box
Option: for dynamic test purpose only
9118
1
Test
– In
Test
– Out Normal connection for operation
9137
1
Tx-out
PA Input
H155 coax, 1.5 m
Table 1
: Cable Connections