STBY NORM
RATIO A/B
F R E Q P E R
A A
MHz
lOOMHz-MAX FREQ
1 Hz 1OHz 1OH - R E S O L U T I O N
N T - A V E R A G E
C H A N
B
I
VEL A
SLOPE ATTN SLOPE
X l
SEP
NOTE
See Table 7-7 for specifications on all input signals concern-
ing bandwidth, accuracy, and amplitude.
1. Set line switch
to the ON position.
2. Set COM A/SEP switch
to SEP position.
3. Place the two function switches
in the OUT position. This places the HP 5314A in
the Ratio A to B function.
4. Connect the higher frequency signal to the
INPUT
A
jack
Connect the lower frequency
signal to the INPUT B jack
(the higher frequency can be input to INPUT B
if
it is below
2.5 MHz).
5. Set SLOPE switches and
ATTN switch
and LEVEL A and B controls
to desired positions; see Table 1-1, Specifications,
for details.
6. Press the desired sample size switch
)
For an explanation of the sample size
switches, see Figure 3-2,
and