79
Bit 6
Reserved
Bit 7
Originate/answer
Originate/answer 0:
Answer
mode
1:
Originate
mode
S15*
DTC Time Settings
The idle connection control is a function integrated in the firmware which moni-
tors the data transmission in online mode. This function prevents the modem to
stay online for an unlimited amount of time, although no data is being transmitted
anymore.
In the registry S15, any time period between 1 and 255 seconds may be entered. If
S15 is set to 0, the idle connection control is switched off.
The timer will run immediately after the modem goes off-hook. As soon as the
timer has run out, a modem reset is performed (which will forcibly lead to the
hanging up of the modem).
S17*
Initial character for remote configuration
In S17, the ASCII code of a character which is used to start the remote configura-
tion, is defined. Values >127 switch the remote configuration off completely. The
default setting in S17 is “42”, which equals the ASCII character “*”. This means
that the remote configuration is started with the Escape character sequence
<Pause> **** <Pause>.
Note: The number of characters in the Escape sequence is fixed to “4” characters).
S21*
Settings for V24
Bit Meaning
Bit 0.1
Reserved
Bit 2
CTS behavior
CT106 (CTS) behavior:
0: see AT\K0
1: see
AT&R1
Bit 3-4
DTR behavior
CT108 (DTR) behavior:
0: see
AT&D0
1: see
AT&D1
2: see
AT&D2
3: see
AT&D3
Bit 5
DCD behavior
CT109 (DCD) behavior:
0: see
AT&C0
1: see
AT&C1
Bit 6
DSR behavior
CT107 (DCD) behavior:
0: see
AT&S0
1: see
AT&S1
Bit 7
Reserved
Reserved