Helmholz Modem 56k 4.1
11
4.5.2
Initial operation using HSComm
4.5.2.1
Serial interface
Control/PC and the modem must be modulated via the following joint settings of
the serial interface:
¾
Baud rate (Data transmission speed)
¾
Format (Start bit, data bits, parity, stop bits)
¾
Data flow control (Hardware/software handshake)
PC Settings
Serial interface settings of the PC (
Interface
menu) – the current settings are dis-
played in the message bar of the main window.
This setting must also be entered at the application (e.g. SPS), which is later con-
nected to the HELMHOLZ modem 56k 4.1.
Settings at the HELMHOLZ modem 56k 4.1
Handshake setting at the modem (
Configure menu
Æ
Modem
):
Auto bauding: With the first AT command, the HELMHOLZ Modem 56k 4.1 recog-
nizes the baud rate and the format of the incoming data and configures itself ac-
cordingly. When the modem doesn’t receive AT commands but user data right
away, the last saved settings are kept.
If more data is available than what can be received by the modem, the handshake
will regulate the data flow.
Содержание 700-751-HSM11