70
Helmholz Modem 56k 4.1
Command Description
ATX<n>
Extended result messages, dial tone detection
The command determines which group of messages the modem sends to the PC.
This is important for PBXs, as often a leading 0 or 9 must be dialed before a dialing
tone is heard on the line.
Blind dialing
(dialing without detecting the dialing tone)
is activated or deactivated according to the parameter. The detection of the dialing
tone, however, can always be enforced using the parameter W in the
ATD
dialing
string (see command
ATD
). In the mode
AT+FCLASS=1,2,
the modem always
sends the message
CONNECT
to the PC without specifying the transmission speed.
ATX0
No detection of the dialing tone, i.e. an unsuccessful dialing attempt
leads to the message
NO CARRIER
.
No detection of the busy signal, i.e. when calling a busy line the
message
NO CARRIER
is displayed. The message is displayed with-
out specifying the speed.
ATX1
As
ATX0
, but the
CONNECT
message contains the speed specification.
ATX2
Dialing tone detection is active, i.e. a dialing attempt without the
presence of a dialing tone leads to the message
NO DIALTONE
.
No detection of the busy signal, i.e. when calling a busy line the
message
NO CARRIER
is displayed.
ATX3
No detection of the dialing tone, i.e. an unsuccessful dialing attempt
leads to the message
NO CARRIER
.
Busy signal detection active, i.e. when calling a busy line the mes-
sage
BUSY
is displayed.
ATX4
Dialing tone detection is active, i.e. a dialing attempt without the
presence of a dialing tone leads to the message
NO DIALTONE
.
(de-
fault)
Busy signal detection is active, i.e. when calling a busy line the mes-
sage
BUSY
is displayed.
AT*X
Terminate remote configuration
The command
AT*X
terminates a remote configuration.
AT&Y<n>
Selection of user configuration for hardware reset
AT&Y0
For a hardware reset following the
AT&Y0
-command, the user de-
fault 0 (created using the
AT&W0
command) is loaded into the cur-
rent modem configuration.
AT&Y1
For a hardware reset following the
AT&Y1
-command, the user de-
fault 1 (created using the
AT&W1
command) is loaded into the cur-
rent modem configuration.
AT*Yx,y
Switch
outputs
x
:
Port (OUT1=0, OUT2=1)
If no port is specified (x), OUT1 is used
y
:
Desired condition of the output (relay open =0, relay closed =1)
Default:
AT*Y0,0
AT*Y1,0
Содержание 700-751-HSM11