Helmer Scientific i.Series
®
Platelet Incubator
Operation Manual
360388/A
4
Symbols found on the units
The following symbols may be found on the incubator or incubator packaging:
CE Mark (European units only)
Earth / ground terminal
Caution: Risk of damage to equipment or
danger to operator
Protective earth / ground terminal
Caution: Hot surface
Product falls under the scope of the WEEE
(Waste Electrical and Electronic Equipment)
directive.
Caution: Shock / electrical hazard
1.5
Avoiding Injury
Review safety instructions before installing, using, or maintaining the equipment.
♦
Before moving unit, remove the installed agitator (if applicable).
♦
Before moving unit, ensure door is closed.
♦
Before moving unit, disconnect the AC power cord and secure the cord.
♦
When moving unit, use assistance from a second person.
♦
Never physically restrict any moving component.
♦
Avoid removing electrical service panels and access panels unless so instructed.
♦
Do not store or place objects or liquid containers on top of the incubator.
♦
Keep hands away from pinch points when closing the door or when agitation motion is enabled (if applicable).
♦
Avoid sharp edges when working inside the electrical compartment.
♦
Ensure biological materials are stored at recommended temperatures determined by standards, literature, or good
laboratory practices.
♦
Proceed with caution when adding and removing product from the platelet incubator.
♦
Use manufacturer supplied power cord only.
♦ Using the equipment in a manner not specified by Helmer Scientific may impair the protection provided by the equipment.
♦ The platelet incubator is not considered to be a storage cabinet for flammable or hazardous materials.
CAUTION
Decontaminate parts prior to sending for service or repair. Contact Helmer Scientific or your distributor for
decontamination instructions and a Return Authorization Number.
1.6
General Recommendations
General Use
Allow platelet incubator to come to room temperature before switching power on.
During initial startup, motion alarm may sound if the motion is disabled, and low temperature alarm may sound while platelet
incubator reaches operating temperature.
Initial Loading
After platelet incubator reaches room temperature, allow chamber temperature to stabilize at the setpoint before storing product.