HM1525 Weigh Scale Module
Page 10
OUTPUT TAG DESCRIPTIONS
MSF BITS
– (Motion Stabilization Filter)
Used for applications with constant or static type loads to keep display value stable.
MSF1_2 (1 count up
– 2 counts down).
MSF2_4
MSF4_8
MSF5_10
Set one bit only.
ZERO-DEAD-BAND BITS
Useful for Auto-Tare functions with production runs.
Set only one bit.
ZEROBAND_025 = .025% full scale
ZEROBAND_05 = .05% full scale
ZEROBAND_075 = .075% full scale
Auto tare occurs when load cell weight is at bit level or lower.
READ MV/V BIT
Check verify mV/V settings
READ CAL FACTOR BIT
Check auto cal values
SAVE TO EEPROM
Stores CH1/CH2 scale settings
AUTO CAL MODE
Set to “1” for auto cal mode
SET CH1 SCALE BIT
Set to “1” to set CH1 scale
SET CH2 SCALE BIT
Set to “1” to set CH2 scale