9
STEP 1S –
Press NEXT and
simultaneously for 3 seconds until display changes. If screen
in Step 2S does not appear in 5 seconds the lock on the valve is activated.
STEP 2S –
Choose SOFTENING using
or
button. Press NEXT to go to Step 3S. Press
REGEN to exit Softener System Setup.
STEP 3S –
Select the time for the first cycle (which in this example is FILL) using the
or
button. Press NEXT to go to Step 4S. Press REGEN to return to previous step.
STEP 4S –
Select the time for the second cycle (which in this example is SOFTENING) using
or
button. Press NEXT to go to Step 5S. Press REGEN to return to the previous step.
STEP 5S –
Select the time for the third cycle (which in this example is BACKWASH) using the
or
button. Press NEXT to go to Step 6S. Press REGEN to return to the previous step.
STEP 6S –
Select the time for the fourth cycle (which
in this example is dn BRINE) using the
or
button.
Press NEXT to go to Step 7S. Press REGEN to return
to the previous step.
STEP 7S –
Select the time for the fourth cycle (which in this example is 2nd Backwash) using
the
or
button. Press NEXT to go to Step 8S. Press REGEN to return to the previous
step.
CYCLE TIME ADJUSTMENTS
Normally it is not recommended to adjust the lengths of the cycle times. However, certain water conditions may
dictate adjustments. This should only be done from the recommendation of a water conditioning professional.
The following charts shows the upper and lower limits of each cycle.
STEP 1S
STEP 2S
Figure 12a
Cycle Options
Units
Lower/Upper Limit Factory Setting
Fill
Lbs.
0.1 to 5200
See Page 28
Softening (Service)
Minutes
1 to 480
120
Backwash
Minutes
1 to 120
8
Brine
Minutes
1 to 180
60
Backwash
Minutes
1 to 120
8
Rinse
Minutes
1 to 120
4
STEP 5S
BACKWASH
MIN
STEP 4S
MIN
SET
SOFTENING
STEP 7S
BACKWASH
STEP 3S
FILL
LBS
STEP 6S
MIN
BRINE
MIN
BRINE