93 / 179
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without
express authorization is prohibited. Offenders will be held liable for the payment of damages.
All rights reserved in the event of the grant of patent, utility model or design.
21.04.2020
Version 1.18.0
Configuration
APS-90, APS-180 and APS-90-Outdoor-PoE
■
For a live view click the button (Fig. 76 /4). The button changes to a button
during live view.
■
To refresh view if live view is paused click the button (Fig. 76 /5). The button is
deactivated during live view.
■
To change the brightness of the live view use the slider control (Fig. 76 /6). Slide to the
right for a brighter view. Slide to the left for a darker view.
■
To toggle between different indicators for objects use the
Mark objects
button
●
off (Fig. 76 /7)
●
with points for detected people only (Fig. 76 /2)
●
off
●
with points and info text as id and height (Fig. 76 /1)
6.3.2
Device information
The device displays a diagnostic status.
Fig. 77: Device information
Optical Self Diagnosis (OSD) Status
OK
Normal state.
Covered
One or both cameras covered, e.g. by a sticker.
Too dark
Illumination is too low for proper function or both cameras are
completely covered and show a black image.
Too bright
Illumination is too bright for proper function.