![Helios B AVD Series Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/helios/b-avd-series/b-avd-series_installation-and-operation-instructions-manual_2121015046.webp)
EN
16
B AVD.. and B VAR.. – Smoke Extraction Fans F300/F400/F600
Installation and Operating Instructions
4.4 Standstill and disposal
WARNING
When dismantling, live parts can be exposed, which can result in electric shock if touched. Before dismantling,
isolate the unit from the mains power supply and protect against being switching on again!
The generally applicable safety at work and accident prevention regulations must be observed!
– Electrical work must only be carried out by an authorised electrician
– Fully isolate electrical connection from mains power supply
– Use appropriate lifting equipment and fastening devices to dismantle the fan
– Observe the instructions in the electric motor maintenance manual for decommissioning the motor
– Dispose of the fan components according to the valid rules and laws
5.0 Technical data
Protection class:
Motor: IP 55
Insulation class motor winding: H
Temperature class:
F300, F400, F600
Max. air flow temperature:
s1 = -20 to +40°C
s2 = up to 300 °C/120 Min.,
400 °C/120 min. and
600 °C/120 min.
Max. weights:
CHAPTER 5
TECHNICAL DATA
Type
Temperature class Weight up to max.
Type
Temperature class
Weight up to max.
B VAR.. 280
F300
24 kg
B VAR.. 315
F300
26 kg
B VAR.. 355
F300
43 kg
B VAR.. 400
F300
76 kg
B VAR.. 450
F300
106 kg
B VAR.. 500
F300
191kg
B AVD.. 500
F300
43 kg
B VAR.. 560
F300
106 kg
B AVD.. 560
F300
56 kg
B VAR.. 630
F300
167 kg
B AVD.. 630
F300
66 kg
B VAR.. 710
F300
244 kg
B AVD.. 710
F300
122 kg
B VAR.. 800
F300
339 kg
B AVD.. 800
F300
140 kg
B VAR.. 900
F300
551 kg
B AVD.. 900
F300
251 kg
B VAR.. 1000
F300
708 kg
B AVD.. 1000
F300
334 kg
B AVD.. 1120
F300
486 kg
B AVD.. 1250
F300
604 kg
B VAR.. 500
F400
84kg
B AVD.. 500
F400
43 kg
B VAR.. 560
F400
106 kg
B AVD.. 560
F400
56 kg
B VAR.. 630
F400
167 kg
B AVD.. 630
F400
66 kg
B VAR.. 710
F400
244 kg
B AVD.. 710
F400
122 kg
B VAR.. 800
F400
339 kg
B AVD.. 800
F400
140 kg
B VAR.. 900
F400
551 kg
B AVD.. 900
F400
251 kg
B VAR.. 1000
F400
708 kg
B AVD.. 1000
F400
334 kg
B AVD.. 1120
F400
486 kg
B AVD.. 1250
F400
604 kg
B VAR.. 500
F600
96kg
B AVD.. 500
F600
66 kg
B VAR.. 560
F600
134 kg
B AVD.. 560
F600
79 kg
B VAR.. 630
F600
196 kg
B AVD.. 630
F600
98 kg
B VAR.. 710
F600
297 kg
B AVD.. 710
F600
141 kg
B VAR.. 800
F600
407 kg
B AVD.. 800
F600
198 kg
B VAR.. 900
F600
648 kg
B AVD.. 900
F600
309 kg
B VAR.. 1000
F600
865 kg
B AVD.. 1000
F600
395 kg
B AVD.. 1120
F600
642 kg
B AVD.. 1250
F600
850 kg
WARNING
nm