79
Change the controller.
2
241
FLASH
CHECKSUM
Flash memory
fault
After the key is turned on, the program in flash memory
is positive value. Fault occurs when it is negative
value.
Fault analysis: it is the fault of flash memory. The flash
memory may be damaged. Or the memorized program
is damaged. Try to reset the logic card program. If fault
still occurs, it is the fault of microcontroller. Change the
controller.
2
242
ENCODER
LOCKED
Encoder
feedback
signal fault
Normally, if target speed is higher than 10hz and the
motor speed is higher than 1.5hz, the encoder feedback
signal should be higher than a set value. If it is not like
this, the controller alarms. Check the encoder, motor,
motor wiring, installment way. If all are right, change
controller.
2
243
SENS MOT TEMP
KO
Temperature
sensor
fault
Phenomenon: motor temperature sensor output signal
exceeds range.
Remedy: check sensor value and wiring condition. If all
is right, the interior of the controller has fault.
2
244
SOFTWARE
ERROR
Software fault Causes of this fault are many, such as CAN bus fault,
EEPROM FAULT and so on. check the “DEBUG
MODE”, it should be “OFF”.
2
245
WRONG
RAM
MEMORY
Dynamic
memory fault
Fault is detected when checking the main memory. The
resisted address is “DIRTY”. The fault will limit the
operation of truck.
Remedy: turn off the key switch and turn it on again. if
fault still occurs, change the controller.
2
247
DATA
ACQUISITION
Data
acquisition
When adjusting current gain, fault alarms. Nothing
need to be done. The fault will disappear after
adjusting.
2
248
NO
CAN
MESSAGE
No
CAN
message
CAN communicating fault between pump and traction.
Check the CAN wiring software setting and edition
information.
2
249
CHECK UP NEED
Maintenance
time
It is time to maintenance and check the truck.
2
250
THERMIC
SENS KO
Temperature
sensor fault
The output signal of controller temperature sensor
exceeds range.
Change the controller.
2
251
WRONG SET
BATTERY
Battery setting
fault
When starting, controller checks battery voltage if it is
within the nominal range. Check if the “BATTERY
VOLTAGE” parameter in TESTER is the same
with the value shown on the voltmeter. If they are not
the same, adjust the battery voltage through
Содержание CQD16X1