4. Usage
If
shifting priority function is ON, and ambient temperature is lower than [3.04]
,
unit
works as shown
below:
House heating water under water temp.
The running time for DHW
is cleared. Unit Starts heating
and counting the running time.
Unit keep on working in DHW
and counting the running time.
The ambient temp.
Is below (3.04)
Whether the
unit works in
DHW
Whether unit works
in DHW over (3.05)
Whether house heating water
temperature drops over (3.07)
Whether unit works in
Heating over (3.06)
The running time for Heating is
cleared. Unit starts DHW and
counting the running time.
Unit keep on working in Heating
and counting the running time.
Unit works in heating
YES
NO
YES
YES
YES
YES
NO
NO
NO
84