With this application, it can not only ensure the volume of high temperature hot water, but also ensure the
water flow rate of heat pump system. But the total cost will be higher than other two applications due to the
cost the plate heat exchanger.
For all these three applications, it is recommended to add a manual mixture valve between city water inlet
and water tank sanitary hot water outlet. This can maximize the utilization of hot water in the tank and also
ensures its temperature won
'
t be too high to burn people.
If the structure of the tank permits, it is suggested to use a manual 4-way mixture valve in sanitary hot water
system as shown below. This can further improve the utilization of hot water in the tank
.
Water inlet from
heat pump
Water inlet from
heat pump
Magnesium rod
T/P valve
4-Way water
mixture valve
City water
High temperature hot water export
Water mixture
valve
Magnesium rod
T/P valve
City water
Water to water plate heat
exchanger
Water from
heat pump
Water to
heat pump
3) Application 3
A water to water plate heat exchanger can be used instead of the coil inside water tank, as shown below:
3. Installation
48