When connecting the power cable between the monoblock unit and indoor control unit, cables
connected to the terminal block in indoor control unit must match these in monoblock unit.
For example, if the terminals and power cables are connected as
→
gree/yellow cable, L
→
red cable
,
N
→
blue cable
,
S
→
black cable in indoor control unit, the connections in the monoblock unit should be
in the same way.
3. Installation
4.1) Power cable between indoor control unit and monoblock unit
Prepare a 3 cores power cable with suitable length that complies the local safety regulations,
A. Insert one end of this cable through the cable gland on bottom of the indoor control unit, and connect
this power cable to "Outdoor power supply" on indoor control unit terminal block.
B. Fasten the cable gland to ensure the cable won't get loosen.
Connect cable between indoor control unit and monoblock unit to correspondent terminal block
according to the wiring diagram. Fasten the cable gland to ensure the cable won't get loosen.
C
.
C
B
A
Shown as "Outdoor
power supply" on wiring
diagram
68