![Hedson IRT System Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/hedson/irt-system-series/irt-system-series_operation-manual_2118433013.webp)
13
196349 rev 1
EN
Yearly
Plan to change the air filter approx. once per year. You
will get a message in the software when it is time to
change. When starting up the dryer you will get an indi-
cation on how much of the filter time that is used.
Regular safety inspection. Inspection report, see 12.1.
Every 2 operating years
Replace the safety valve.
Every 6 operating years
Replace the complete set of air hoses.
10.2 IRT lamp replacement
Note!
Disconnect the cassette from the heaters mount-
ing frame of the dryer before service.
Attention!
Do not touch either the gold coated reflector or the new
IR lamp with your fingers. Only remove the protective
paper on the IR lamp after you have installed it.
Remove lamp
Attach lamp
Keep the protection paper around the lamp until the fit-
ting is completed.
1. Loosen the mounting
screws on both end cov-
ers.
2. Loosen both lamp end
protections.
3. Pull the protection out of
the slide. The screws for
the lamp holders will be
accessible
4. Loosen the lamp end
screws and remove the
lamp.
5. Fix the lamp in one of the
Lamp holders. Make sure
that the terminal strip
gets as far as possible
underneath the square
clamp. Fasten the screw.
Bend the other lamp end
with the finger and fix it
as the first one.
6. Focus the IRT-lamp by
centralizing it sideways
in the reflector body.
7. Focus the IRT-lamp by
centralizing it lengthways
in the reflector body
Remove the lamp protec-
tion paper.
8. Push the protection
back into the slide and
attached the end covers.
10.3 Filter replacement
Attention!
The filters are disposable and should not be reused.
1. Use a knife or screw driver to open the filter box.
2. Remove the used filter.
3. Insert the new filter.
4. Close the filter box.
Содержание IRT System Series