9.4.23  51 Power Rating 3

Possibilities to independently the other outputs give the 
power rating for output 3.

Option:

 0-99.9 kW where 0.0 is inactive.

9.4.24  52 Pyro Regulator P (Propotional)

This option, together with 9.4.25, is used to fine tune the 
heating system depending on the pyrometer readings.

9.4.25  53 Pyro Regulator I (Integral)

This option, together with 9.4.24, is used to fine tune the 
heating system depending on the pyrometer readings.
By tuning the two parameters P and I in the PID control-
ler algorithm, the controller can provide control action 
designed for specific process requirements. The re-
sponse of the controller can be described in terms of the 
responsiveness of the controller to an error, the degree 
to which the controller overshoots the set point, and the 
degree of system oscillation.
To alter the values for P and I full understanding of PID 
controllers is needed. 
If this knowledge is not at site, please contact Hedson 
Technologies AB if this needs to be adjusted.

9.4.26  54 Output 2 Scale

Possibility to control the level of power on output 2 from 
0-100% compared to output 1. Default is 100%

9.4.27  55 Output 3 Scale

Possibility to control the level of power on output 3 from 
0-100% compared to output 1. Default is 100%

9.4.28  56 Proc. Alarm Temp.

Possibility to set maximum temperature difference be-
tween current and requested temperature (5-99ºC). This 
function is activated in 9.4.3.

9.4.29  57 Continuous Mode 

Possibility to decide if the IRT dryer should have continu-
ous drying or time dependent drying. Yes = Continu-
ous drying. No = Machine stops when time countdown 
reaches 0.

10. Maintenance and Service

Maintenance work is to be carried out at the stipulated 
maintenance intervals by suitably trained personnel.
Do not use running water or flammable liquids for clean-
ing.
Abide by the following points to ensure a long service 
life and continuous operation of the dryer:

Only original spare parts and suitable tools are to be
used.

Adhere to the maintenance intervals.

Contact your dealer or the manufacturer’s customer
service department regarding any maintenance
work that is not listed or shown in this manual.

Only undertake maintenance work when the maximum 
lift (unloaded) is reached, the platform table has been 
reinforced by service supports (part no. 195682) or 
secured by a forklift at the top position and the com-
pressed air supply and electricity has been shut off.

10.1  Maintenance

Weekly

 

Check that all IR lamps light up during dryer operation. 
Defect IR lamps can cause uneven heat distribution over 
the surface.
Clean the dryer from dust, which can be a cause of fire, 
with a damp cloth. 
Check that all cables are undamaged. A damaged cable 
can be a danger to life!

Monthly

 

Check the gold coated reflectors. Damaged or extremely 
dirty reflectors can overheat the reflector body and/
or the cassette. In case of doubt, please contact the 
customer service in order to clarify if the gold coated 
reflector needs to be changed.

Check all moving parts such as pivot bolts, sliding pieces 
and sliding surfaces for wear and tear; clean and lubri-
cate. Only use greases in the lacquer coated sections 
that do not contain substances that might damage the 
lacquer coating.

Check air bellows and air hoses for damage. Inspect 
visually and check for leaks. Check the surface of the air 
bellows for contamination; clean and maintain. Always 
use appropriate care and cleaning products when carry-
ing out maintenance on the rubber surfaces.

Check that the valves are working correctly and check for 
leaks.

Inspect the service unit provided by the customer (filter 
regulator) and abide by the instructions in the manufac-
turer’s manual.

Содержание IRT System Series

Страница 1: ...196349 rev 1 Hedson Technologies AB 2018 IRT Dryer Siemens Leading Edge Protection EN Operation Manual original language...

Страница 2: ...wner 5 5 Assembly instruction 5 6 Basic instruction for operation 5 7 Program mode 8 8 Extended usage information 9 9 Settings mode 9 10 Maintenance and Service 12 11 Spare parts 14 12 Safety inspecti...

Страница 3: ...ounted on the lifting platform 1 Safety instructions 1 1 Operator s duty of care The IRT Siemens Leading Edge Protection Dryer is designed and built after a hazard assessment was con sidered and follo...

Страница 4: ...king under the raised working platform and during its lifting and lowering movements is not permitted 3 Product description The IRT Siemens Leading Edge Protection Dryer is a maneuverable infrared dry...

Страница 5: ...ir only A filter regulator must only be installed in the air supply line air filter and water separator 6 Basic instruction for operation Move the dryer to the site where you want to use it This can o...

Страница 6: ...amps Control panel 1 The lights turn green when the correct distance obtained between IR lamps and object This distance must be checked before the IR lights turned on During operation with IR lamps th...

Страница 7: ...ered This is normally not a part of the everyday usage To enter the settings mode press both arrow keys when you turn the main switch to position 1 Read chapter 9 for more information 6 8 Program inte...

Страница 8: ...is finished If this happens check the cooling system of the con trol unit fan filter or ambient temperature 3 Paint Temperature Alarm Also called Process alarm see 8 2 Option if pyrometer is used 4 Fi...

Страница 9: ...ram is terminated In case of process alarm check if the temperature measuring device pyrometer is aligned correctly on the surface to be dried and that it is not registering unwanted material temperat...

Страница 10: ...o select no yes Press select to confirm 9 4 6 7 Basic PIN Code You can change the PIN code to prevent unauthor ized access to the basic setting as described in table in chapter 9 4 To do this use the...

Страница 11: ...t 4 Cassette IR Test The IR cassette lamps output I light up Check that all the IR lamps are lit For safety reasons this test is limited to 10 seconds Press enter or next to continue Test 5 Ventilator...

Страница 12: ...uitably trained personnel Do not use running water or flammable liquids for clean ing Abide by the following points to ensure a long service life and continuous operation of the dryer Only original sp...

Страница 13: ...round the lamp until the fit ting is completed 1 Loosen the mounting screws on both end cov ers 2 Loosen both lamp end protections 3 Pull the protection out of the slide The screws for the lamp holder...

Страница 14: ...st environmental pro tection facility for recycling 11 Spare parts The following spare parts are the most common ones for the SingleHeater IR units Part Part nr 1 Fan 202024 2 Filter 103055 3 IR lamp...

Страница 15: ...s to the zero position when released Fall arrester function Emergency release status Air bellows status Supporting structure status Function test Lifting lowering Function test Lifting lowering with l...

Страница 16: ...lowing standard s or other normative document s EN 61000 6 4 Electromagnetic Compatibility Generic Emission Standard EN 61000 6 3 Electromagnetic Compatibility Generic Immunity Standard EN 60204 1 Saf...

Страница 17: ...appendix 1 761 054_PNTS 77 Electrical diagram for IRT Siemens Leading Edge Protection Dryer equipment is found in the appendix 2 15 Weights and Dimensions The overall weight is 665 kg Dimensions as b...

Страница 18: ...sette tripped Check fans filters hoses and ambient tempera ture Reset by pressing the temp switch button Lifting malfunction Maintenance unit manometer without mains pressure Ensure the mains pressure...

Страница 19: ...70 196349 rev 1...

Страница 20: ...53 42 00 Telefax 46 0 40 43 29 01 www hedson com HEDSON TECHNOLOGIES AB Box 1530 SE 462 28 V nersborg Tel 46 0 40 53 42 00 Telefax 46 0 521 669 09 www hedson com Hedson Technologies 2017 The manufact...

Отзывы: