1
GAS (LPG) TANK INFORMATION
1 Maximum diameter: 30 cm
2 Maximum height: 60 cm
3 Maximum NET Weight: 10 kg
DIMENSION AND CLEARANCE INFORMATION
IMPORTANT 1
: MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL, FROM
TOP 500mm, SIDE 1000mm, FRONT 1000mm, REAR 300mm.
IMPORTANT 2
: ALWAYS LOCATE AND OPERATE HEATER ON A FLAT-LEVEL SURFACE.
Country Code
Gas Category
Jet Size
Model
Input
BE,CY,DK,EE,FR,GB
HU,IT,LT,NL,NO,SE
SI,SK,RO,HR,TR,BG
IS,LU,MT,FI
I3B/P(30)
I3+(28-30/37)
I3B/P (50)
9.4KW (G30:684g/h, G31:672g/h)
WARNING:
Read the instructions before using this appliance.
- The appliance must be installed in accordance with the instructions and
local regulations.
- The use of this appliance in enclosed areas can be dangerouse and is
PROHIBITED.
- For use outdoors or in amply ventilated areas. An amply ventilated are must
have a minimum of 25% of the surface area open. The surface area is the sum
of the walls surface
.
- Clearance from combustible materials, Top 500mm, Front 1000 mm, Side
1000mm, Rear 300mm.
- Close the valve of the gas cylinder or the regulator after use.
Manufactured by
Thermofilm Australia Pty Ltd
P80681006A
BE,CH,CY,CZ,ES
FR,GB,GR,IE,IT,LT
LU,LV,PT,SK,SI
Gas and
Pressure
G30 Butane at 28-30 mbar
G31 Propane at 37 mbar
G30 Butane and G31
Propane at 50mbar
G30 Butane and G31
Propane at 30mbar
AT,CH,DE,SK
Outdoor Radiant Gas Heater
Product Name
Model Type
TGH34PL
Portable
0.73 mm
0.66mm
ENGLISH
Содержание TGH34PL