TECHNICAL SPECIFICATIONS
GE/N 250C
GE/N 400C
Natural gas
Supply pressure
[in WC]
min 7" w.c.
max 10" w.c.
min 7" w.c.
max 10" w.c.
Selector valve position
Normal
altitude 0 -
2,000 ft above
sea level
(U.S.A. and
Canada)
Heat input
[BTU/h]
254.684
403.753
Manifold pressure
[in WC]
4,33
4,40
Fuel consumption
[CFH]
241,52
381,35
Altitude 2,000
- 4,500 ft
above sea
level (Canada
only)
Heat input
[BTU/h]
229.216
363.378
Manifold pressure
[in WC]
4,11
4,18
Fuel consumption
[CFH]
217,37
343,21
L.P.G.
Supply pressure
[in WC]
min 8" w.c.
max 13" w.c.
min 8" w.c.
max 13" w.c.
Selector valve position
Normal
altitude 0 -
2,000 ft above
sea level
(U.S.A. and
Canada)
Heat input
[BTU/h]
241.413
394.134
Manifold pressure
[in WC]
4,28
4,50
Fuel consumption
[CFH]
88,98
145,12
Altitude 2,000
- 4,500 ft
above sea
level (Canada
only)
Heat input
[BTU/h]
217.272
354.721
Manifold pressure
[in WC]
4,06
4,27
Fuel consumption
[CFH]
80,08
130,61
Air flow
[cfm]
2.766
4.120
Power supply
Phase
1
1
Voltage
[V]
120
120
Frequency
[Hz]
60
60
Electric consumption
[W]
500
900
[A]
5,0
8,5
Ring nozzle
[in]
N. 16 holes x 0,079"
N. 16 holes x 0,102"
Gas inlet connection thread
3/4" NPT
3/4" NPT
Air distribution
duct
Max Static pressure
[in]
0,60
0,56
Max length
[ft]
50
50
Noise level at 1 m
[dBA]
77
74
Heater
Dimensions, L x W x H
[in]
40,6 x 24,6 x 21,7
56,,1 x 29,5 x 25,7
Weight
[lb]
101
192
Packaging
Dimensions, L x W x H
[in]
42,3 x 21,9 x 29,45
57,7 x 24,4 x 32,6
Weight
[lb]
134
225
4
Operating Instructions and Owner’s Manual
ENERCO GROUP, INC. |Indirect Fired Portable Heater