![Heatrae Sadia STREAMLINE OVERSINK 95010281 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/heatrae-sadia/streamline-oversink-95010281/streamline-oversink-95010281_fitting-instructions-and-user-manual_2117711014.webp)
14
7.0 FAULT FINDING
WARNING: DISCONNECT FROM ALL ELECTRICAL SUPPLIES BEFORE
BEGINNING ANY WORK ON THE WATER HEATER. WATER CONTAINED
IN THE WATER HEATER MAY BE VERY HOT!
The Streamline should give trouble free operation, however should a problem
occur, the table below should enable most faults to be identified with ease.
Fault Finding should be carried out by a competent person and any
replacement parts used should be authorised Heatrea Sadia spare parts.
TABLE 02: FAULT FINDING
SYMPTOM
PROBABLE CAUSE
ACTION
No water
Mains water not turned
on.
Check supply and turn
on.
Insufficient mains
pressure.
Check supply.
Blockage in tap.
Clean tap
No hot water
No water in heater.
Fill water heater.
Cut out has operated.
Reset cut out.
Faulty thermostat.
Replace thermostat.
Faulty element.
Replace element.
Water is too hot
Thermostat is set too
high.
Adjust thermostat.
Faulty thermostat.
Replace thermostat.
NOTE: THE WATER IN THE STREAMLINE WILL EXPAND DURING HEATING
CAUSING THE TAP TO DRIP. THIS IS NORMAL AND IS NOT A FAULT WITH
THE STREAMLINE.
7.1 CUT OUT RESET
Disconnect the electrical supply.
1.
Remove the front cover (see section 3).
2.
Depress the red button (see figure 14).
3.
Recommission the Streamline (see section 4).
4.
If the cut out continues to operate contact the Heatrae Sadia Service
5.
Team.