10
4.0 COMMISSIONING
DO NOT SWITCH ON THE ELECTRICAL SUPPLY UNTIL THE STREAMLINE
HAS BEEN FILLED WITH WATER AND CHECKED FOR LEAKS.
Check all water and electrical connections are tight.
1.
Check that the thermostat and cutout capillaries are located correctly in
2.
the element pockets.
Switch on the water supply and open the control valve. Fill the Streamline
3.
and leave the water flowing for a short while to flush out the pipework.
Close the control valve and check the system for leaks.
4.
Refit the front cover and x2 securing screws.
5.
Fit the thermostat knob (see figure 10).
6.
Fit the control valve extension (see figure 11)
7.
Fit the control valve knob (ensure the control knob is engaged with the
8.
control valve extension and snaps to the front cover).
Set the temperature.
9.
The maximum setting is 70°C and the minimum is
5°C. Rotate the thermostat knob clockwise to increase the temperature,
and anticlockwise to decrease the temperature . Settings above 60°C
are recommended.
Switch the power on and check the water heats (see Table 1 for heat
10.
up times).
Check the temperature and adjust if needed.
11.
NOTE:
The thermostat can be locked in position to set the water temperature
•
to 40°C.
Remove the locking screw from the inside of the front cover and refit it to
•
the outside of the front cover (see figure 10).
Align the locking detail on the inside of the thermostat knob to the locking
•
screw when fitting the thermostat knob in place.
FIGURE 10 - THERMOSTAT KNOB
SPINDLE
SCREW DRIVER
RECESS
LOCKING
DETAIL
THERMOSTAT
KNOB
LOCKING SCREW